- ページ 8
照明器具 Gamma Luxe Rose XT 200Z VWのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Gamma Luxe Rose XT 200Z VW 12 ページ。 200w cold white/warm white fresnel with motorized zoom
32 Fixture Rule – DMX only allows you to connect up to 32 fixtures in a single daisy
chain for signal strength. Sometimes, depending on the fixtures and cable length, this
number is less (or more).
DMX Cables can be 3-pin or 5-pin. These use the same type of data, and in the 5-pin
only pins 1, 2, and 3 are used. The cable should be a 2 conductor, shielded cable of at
least 110 ohms resistance. Microphone cable is not DMX cable.
Please refer to the diagram below:
For installations where the DMX cable has to run a long distance or is in an electrically
noisy environment, it is recommended to use a DMX terminator. This helps in preventing
corruption of the digital control signal by electrical noise and reflections. The DMX
terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3,
which is then plugged into the output XLR socket of the last fixture in the chain. Please
see illustrations below:
Luxé Rosé XT 200Z VW GAMMA LED Vision
Page 8 of 12