- ページ 5

カメラアクセサリー GREEN BANK LB24150のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。GREEN BANK LB24150 6 ページ。 Lifepo4 battery system for households

LiFePO4 Battery System for Households
Note: One group of LB24V can be stacked up to 4 layers, and up to 6 in parallel connection
One group of LB48V can be stacked up to 2 layers, and up to 6 in parallel connection.
24V Over view
For pure off grid system ,the PV awake wire need to be connected with MPPT charge controller if the battery
pack is charged by solar panels only . The connection diagram as below :

4. OPERATION

Once the batteries are connected well, simply press On/Off button to enable the output of the battery pack.
24V Over view
48V Over view
48V
Over view
06
LiFePO4 Battery System for Households
4.1 Switch On / Off
1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before
enable output. The LED will show the SOC.
2.Switch off: press and hold On/Off button for 3 seconds, the battery will shut down directly.
Description for Communication port
Picture
PIN
1
2
3
4
5
6
7
8
DIP SWITCH
1-4
5

4.2 Description for LED

The SOC of the battery is shown by the LED
100%
75%
Note: The battery need to be fully charged for at least once in one month to ensure the accurate SOC
calculation.
4.3 ON / OFF or SOC Led (Mode or SOC)
ON/OFF
BATTERY MODE
GREEN LED
RED LED
LED1
POWER OFF
OFF
OFF
OFF
POWER ON
OFF
ON
ON
STANDBY
OFF
OFF
NORMAL
ON
OFF
DISCHARGE
ON
OFF
CHARGE
FLASH
OFF
LOW POWER
FLASH
OFF
ON
OFF
ON
OFF
ON
FAULT
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Description
Trigger-GND
Trigger-VCC
NC
COMM-GND
RS485-B
RS485-A
CANL
CANH
Communication Address
Termination Resister
50%
25%
Flashing SOC<10%
SOC
REMARK
LED2
LED3
LED4
OFF
OFF
OFF
ON
ON
ON
SOC
SOC<10%(DEFAULT ): LED1 FLASH
RUNNING/SOC
SOC<10%(DEFAULT ): LED1 FLASH
SOC
SOC<10%(DEFAULT ): LED1 FLASH
RUNNING
OFF
OFF
OFF
OFF
BATTERY VOLTAGE HIGH
ON
OFF
OFF
BATTERY VOLTAGE LOW
ON
OFF
OFF
CELL VOLTAGE HIGH
OFF
ON
OFF
CELL VOLTAGE LOW
OFF
ON
OFF
CHARGING CURRENT HIGH
ON
ON
OFF
DISCHARGING CURRENT HIGH
ON
ON
OFF
BMS TEMPERATURE HIGH
OFF
OFF
ON
BMS TEMPERATURE LOW
OFF
OFF
ON
CELL TEMPERATURE HIGH
ON
OFF
ON
CELL TEMPERATURE LOW
ON
OFF
ON
CURRENT SENSOR ABNOMAL
07