80000434 Issue 1 04/16
Aventa In-line
230V Fan Range
Installation and Operating Guide
Mixed Flow
AV100B – 9041085
AV100T – 9041086
AV125B – 9041087
AV125T – 9041088
AV150B – 9041089
AV150T – 9041090
Electrical installation
AV100B, AV125B
Min Speed
Max Speed
Min/Max Speed
Page 5 of 16
Fan dimensions
Fan specification
Air flow,
Current,
Power,
Type
3
m
/h
Amps
Watts
AV 100/T
145/187
0.11/0.21
21/33
AV 125/T
220/280
0.18/0.27
23/37
AV 150/T
405/520
0.17/0.27
30/60
Page 2 of 16
Electrical installation
AV150B
Min Speed
Max Speed
Min/Max Speed
Page 6 of 16
Range overview
Aventa In-line Mixed Flow fans are available in 3 model
sizes with or without timer function and have 2 speeds.
Aventa In-line Mixed Flow fans can be used as a simple
extract or supply fan where high pressure and flow rates
are required. They can be mounted vertically with a
condensation trap fitted or horizontally. The range has
been designed to accept standard ducting sizes. The
main body of the fan (1) is detachable from the inlet and
outlet spigots and mounting assembly via the 2 clamps
(6). (See diagram below).
Noise
level,
db(A) @
3m
27/36
28/37
33/34
Page 3 of 16
Electrical installation
AV100T, AV125T, AV150T
Min Speed
Max Speed
Page 7 of 16
Electrical installation
The Aventa In-line Mixed Flow range is IPX4 rated and is
suitable for mounting in Zone 2 in bathrooms, toilets,
kitchens, utility rooms when installed with a 30mA RCD.
The fan requires a 230V 50Hz single phase supply. Class II
equipment. BS EN 60417. An external 3A fuse is required
for each fan unit. Cable sizes (max): Fixed flat wiring 2
2
2
core 1mm
, 3 core 1/1.5mm
. All electrical installation to
be carried out by an approved electrician in accordance
with Part "P" U.K. Building Regulations and to the latest
IEEE standards, or the appropriate regulations in the
country of installation.
Important
The Aventa In-line Mixed Flow fan range is IPX4 rated and
complies with the requirements of the EU norms and
directives. Do not place the fan unit near direct heat
sources, e.g. radiant heaters, or where temperatures can
exceed 40°C (104°F).
Precautions must be taken to avoid back flow of gases in
rooms with open flue fuel burning appliances.
Page 4 of 16
Mechanical installation
Determine the orientation of the fan airflow direction by
the use of the flow direction arrow on the fan body (1).
(See diagram on page 3).
Remove the fan body by releasing the 2 clamps (6). Using
the mounting base as a guide mark and drill 4 holes. Use
the wall plugs and screws provided and secure the
mounting base to the mounting surface. Insert the fan
body (1) and secure with the retaining clamps (6). (See
diagram on page 3).
Connect the appropriately sized ducting to the spigot
ducts. Airflow Developments Ltd recommends that rigid
ducting is used instead of flexible ducting, this will help to
ensure maximum performance.
Page 8 of 16