- ページ 2
セキュリティセンサー Green Brook Orion Range OD103のPDF 重要な安全上のご注意をオンラインで閲覧またはダウンロードできます。Green Brook Orion Range OD103 2 ページ。 Infra-red motion detector - ip65
3. Secure the sensor back plate to the wall
using two wood screws (ensure there is no
wiring/gas/water services directly behind
the screws) Dia:3.
4. Position sensor onto back plate and secure using the screw removed in step 1.
1. Turn 'Time' control fully anti-clockwise
and 'Lux' control fully clock wise refer
to Dia: 4.
2. Re-connect mains supply, allow 30
seconds for the sensor to warm-up,
and then perform a walk-by in front of
the sensor; lamp should turn on and
stay on for approximately 10 seconds,
and will go off if no further movement
is detected.
1. Turning Lux control fully clock wise, the sensor will operate in both daylight and
darkness.
2. Turning Lux control fully anti-clockwise, the sensor will operate in darkness only.
3. Set control to operate at your required daylight level.
1. Turning the time control fully anti-clock wise will set the on duration to 10 seconds
+/- 3 seconds.
2.
Turning the time control fully clock wise will set the on duration to 15 minutes +/-
2 minutes.
Light not coming on
•
Check that lamp is good.
•
Check there is nothing obscuring the PIR sensor.
Intermittent operation
•
Check there are no curtains that can move in the wind.
•
Check there are no heating vents nearby.
NOTE:
Product & Packaging Disposal
When disposing of this item and its packaging please follow local
regulations and use an appropriate waste disposal centre.
See GreenBrook website for further details.
ADJUSTING THE 'LUX' CONTROL
ADJUSTING THE 'TIME ON' CONTROL
TROUBLE SHOOTING
TECHNICAL INFORMATION
Rated Voltage:
IP Rating:
Ambient Light:
Time Delay:
Rated Load:
Detection Range:
Detection Distance:
Working Temp:
Working Humidity:
Power Consumption:
Installation Height:
Detection Moving Speed:
Dimensions:
Conforms To:
GUARANTEE
Your GreenBrook Motion Detector IP65
OD103/B is guaranteed for 1 year
from the date of purchase.
This is in addition to your statutory rights.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
www.greenbrook.co.uk
Dia:3
TESTING
Dia:4
230V~50Hz
IP65
<3-2,000 LUX (Adj)
Min 10 sec ± 3 sec
Max 15 min ± 2 min
Max 1200W
Max 300W
180°
12M max (<24°C)
-20° - + 40°C
<93%RH
0.5W approx
1.8 - 2.5M
0.6 - 1.5m/s
119.5 x 80 x 51.5mm
BS EN61058-1
/LED