Route cables and secure foundation plate
1.
Route cables as determined
in Section 9, Cabling
requirements.
Make sure that all cables
protrude at least 400mm
above the baseplate once
installed as shown in the
illustration
2.
Securely concrete or bolt
the foundation plate in
position.
Mount the gearbox
3.
Remove the knock-outs for
the cables from the gearbox.
4.
Feed the cables through
these holes while fitting the
gearbox to the baseplate.
5.
Note how the cables route up
onto the control card.
6.
Check that the operator is
level.
7.
Secure the gearbox in place
fitting the following in
sequence: first a nut and
then a washer onto each
gearbox mounting; then the
gearbox; and then a washer
followed by a spring washer
and finally a nut onto each
gearbox mounting.
8.
Do not mount gearbox flat
down onto mounting plate.
Adjust the height of the
mounting nuts to raise the
gearbox at least 5mm above
the plate. This is to allow for
later adjustments.
9.
Seal the conduit and knock-
out holes in the operator
with silicone sealer to
prevent ants from entering
the operator through these
cable entry points.