- ページ 4
アンプ Majorcom: DPS-480SのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Majorcom: DPS-480S 9 ページ。
6
DPS-240S/360S/480S/720S
Front Panel
Front Panel
720S
MAX
VOL
MIN
1. AC, STBY, DC LED
When Power switch is on, AC or DC leD will illuminate depending on input Power source. When Power
switch is off, StBY leD will turned on. During operation of DC, amplifier is keep going to work even if the
switch of power is turned off.
Power SW
SW oN
AC/DC
SW off
SW oN
AC only
SW off
SW oN
DC only
SW off
2. OUTPUT LEVEL INDICATOR (1CH, 2CH, 3CH, 4CH)
Indicator display of unit's output level status.
SIg(-30dB) leD: green, -10dB leD: green, ClIP leD: orange, PRt leD: Red
※ Note: If ClIP leD is lit, sound output is distorted. Reduce the volume level.
※ Note: for the DPS-720S, if the protection circuit is activated and PRt leD is turned on, turn off the power
and turn it on again.
3. VOLUME CONTROL
Volume adjustments are made. turn clockwise to increase the volume level.
Usermanual V1.1
56, chemin
de la Flambère ·
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] ·
AC
STBY
DC
POWER
Power leD
AC leD
StBY leD
oN
oN
off
off
off
oN
oN
oN
off
off
off
oN
oN
off
off
oN
off
off
31300 Toulouse ·
FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
www.majorcom.fr
4. AIR VENTS
the air circulation passage to prevent overheating of the device, please do not obstruct the flow as air flows
from front to back.
5. POWER SWITCH
Push on/off switch. When Power switch is on, BlUe leD will illuminate.
DC leD
off
off
off
off
oN
oN
DPS-240S/360S/480S/720S
56, chemin
de la Flambère ·
31300 Toulouse ·
FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] ·
7
Usermanual V1.1
www.majorcom.fr