- ページ 3

IPアクセスコントローラ Gantner GAT Access 6600 BのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Gantner GAT Access 6600 B 4 ページ。 Access control terminal with rfid and barcode

Mounting and installation instructions
In order to mount the GAT Access 6600 onto a turnstile, a tubular
mounting holder with 30 mm Ø is used (e.g., a GAT Holder 6010 L). The
connecting cables are fed through the tubular holder and into the housing.
Opening the housing
The housing of the GAT Access 6600 must be opened to install the tubular
holder. Unscrew and remove the 4 housing screws on the rear part while
firmly holding the front part of the GAT Access 6600 to prevent it from
falling. After the screws are removed, the front part can be lifted away.
Two clamps inside the housing are used to fasten the tubular holder. The
lower clamp (1) is directly accessible and can be loosened accordingly to
allow the tubular holder to be inserted.
3
4
3
2
1
In order to gain access to the second clamp (2), the electronics (3) must
be removed. Loosen the two screws as indicated in the figure below (4)
and swing the electronics 90 ° forward (5).
5
4
2x
3
www.gantner.com
4
3
Attachment of the tubular holder and cable installation
Insert the GAT Access 6600 onto the tubular holder (7) until the stop (6)
is reached.
6
2
1
7
Tighten the screws of the two clamps (1) + (2) firmly so that the GAT
Access 6600 is secure and cannot be removed from the tubular holder.
Feed the connecting cables through the tubular holder. Connect the
cables to the screw terminals (see next page). Use cable ties to secure
the cabling to the holes provided in the retaining strip (8).
8
8
7
Remount the electronics in their original position and fasten the 2 screws
(4). Take care not to damage the connecting cable.
Close the housing by placing the front part of the housing onto the
rear part and secure them with the 4 screws. Take care to ensure the
housing gasket is correctly inserted into the joint between the front
and rear part and not damaged during this process.
Valid as from June 16
2015 • Technical data subject to modifications without notice!
th
DB_GAT-ACCESS6600--EN_11.indd • PartNo.: 822630
6
7
6
8
7
3