- ページ 15

ホブ IKEA Lagan HGA4KのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。IKEA Lagan HGA4K 24 ページ。 Ikea hobs instruction manual
IKEA Lagan HGA4K にも: ユーザーマニュアル (16 ページ), 取扱説明書 (24 ページ), ユーザーマニュアル (28 ページ), 取扱説明書 (20 ページ), 取扱説明書 (16 ページ)

IKEA Lagan HGA4K 取扱説明書
ENGLISH
The minimum distance to be maintained
from cut out edge to lateral wall must be
100 mm.
If there is no oven beneath the hob insert a
dividing panel at a minimum distance of 20
mm from the bottom of the hob.
Protect the cut surfaces of the worktop
against moisture using a suitable sealant
included in the product in fitting bag. The
sealant seals the appliance to the worktop
with no gap. Do not use silicon sealant
between the appliance and the worktop.
Avoid installing the appliance next to doors
and under windows as hot cookware may
be knocked off the pan support when doors
and windows are opened.
Gas Connection
Warning! Only a qualified
person must install this
appliance.
Warning! This appliance is not
connected to a combustion
products evacuation device.
Installation must comply with current local
regulation. The connection of the cooktop to
the gas pipe network or gas cylinder must
be made by means of a rigid copper or
steel pipe with fittings complying with local
regulations, or by means of a continuous
surface stainless steel hose complying with
local regulations.
If you see any abnormalities do
not repair the pipe, contact local
After Sales Service (refer to the
Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas.
Warning! Once the installation is
complete, check the perfect seal
of every pipe fixing. Use soapy
water, never flame.
Electrical connection
Before connecting, check that the nominal
voltage of the appliance stated on the
rating plate, corresponds to the available
supply voltage. Also, check the power
rating of the appliance and ensure that the
wire is suitably sized to suit the appliance
power rating (refer to the Technical data
chapter).
Electrical Requirements
Permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your
own safety the installation must be done by
a qualified electrician (e.g. your local
Electricity Board, or a contractor who is on
the roll of the National Inspection Council
for Electrical Installation Contracting
[NICEIC]).
The manufacturer declines any
liability if these safety measures
are not observed.
The appliance must be connected to a
220-240 V 50/60 Hz AC electrical supply.
15
1
2