Install Range Hood
1. Remove screws from wooden shipping supports. Properly
dispose of shipping materials.
2. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
B
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
D. Optional wall anchors (if needed)
3. Remove the grease filter. See "Range Hood Care" section.
4. Level the range hood and tighten upper mounting screws.
5. Install 2 - 5 x 45 mm #2 Phillips lower mounting screws and
tighten. (Use optional wall anchors if needed.)
Connect Vent System
1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm T10 sheet metal screws. Use T10 Torx
(or T10 adapter provided) to tighten.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
C
D
®
drive
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket using
4 - 4.2 x 8 mm T20
®
screws. Use T20
adapter provided) to tighten.
C
A. Assembly screws
B. Air deflector
C. Duct cover bracket
2. Measure from the bottom of the air deflector to the bottom of
the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
3. Cut the duct to the measured size (X).
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket with
the 4 assembly screws.
8. Seal connections with vent clamps.
®
Torx
®
drive (or T20
®
A
B
A
C
X
D. Vent duct
E. Exhaust outlet
9