- ページ 6
換気フード IKEA IHW6362VM0のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。IKEA IHW6362VM0 28 ページ。 30" (76 cm), 35 7/16" (90 cm) wall-mount canopy range hood
Observe allgoverning codes a ndordinances.
Ensure thattheelectrical installation isadequate and in
conformance
withNational Electrical Code, ANSI/NFPA
70(latest
edition), orCSA Standards C22.1-94, Canadian Electrical Code,
Part 1 andC22.2 No. 0 -M91 (latest edition) andalllocal c odes
andordinances.
Ifcodes permit and a separate ground w ire isused, i tis
recommended
thataqualified electrician determine thatthe
ground p athisadequate.
Acopyoftheabove c ode standards canbeobtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA02269
CSA International
8501 East P leasant Valley R oad
Cleveland, OH 44131-5575
•
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
•
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors
and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's
recommended
procedure. Aluminum/copper
connection must conform with
local codes and industry accepted wiring practices.
•
Wire sizes and connections
must conform with the rating of
the appliance as specified on the model/serial
rating plate.
The model/serial
plate is located behind the filter on the rear
wall of the hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22.1-94,
Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
INSTALLATION INSTRUCTIONS
•
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
•
Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect
power.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
It is recommended
that the vent system be installed before
7. Tape template in place, aligning the template centerline and
hood is installed,
bottom of template with hood bottom line and with the
centerline marked on the wall.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A. Centerline
B. Mounting hook location
C. Fastener locations
D. Mounting height reference
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
5=
6.
Determine and mark the centerline on the wall where the
canopy hood will be installed.
Select a mounting height between a minimum of
30" (76.2 cm) and a suggested maximum of 36" (91.4 cm),
above the range to the bottom of the hood and mark
reference line on the wall.
NOTE: For installation locations with reduced ceilings
heights, the vent hood may be installed using the upper vent
cover for both vented and non-vented
(recirculating)
installations.
8. Mark centers of the 6 fastener locations through the template
to the wall.
IMPORTANT: All screws must be installed into wood.
Remove the template.
9. Drill %4" (2.75 mm) pilot holes at all locations where screws
are being installed into wood.
6