Adjusting the line phase
Use an AC power-source synchronization phase
adjustment volume to adjust the phase of power
synchronization (The default position is where the
adjuster is fully turned to the left).
When using the line lock function, the
line frequency should be as follows:
NTSC—60Hz, PAL—50Hz
Adjusting the DC iris level
Adjust the DC iris level to suit the environment in which you are using the
unit. (The default position for the adjuster is in the center.)

Adjusting the camera direction

The camera body is set in a tri-axial mounting allowing movement in the pan, tilt,
and rotational planes. Adjust the direction of the lens so it faces the subject.
Indicates the top of the camera
Using the camera in a near-horizontal position will show the camera
cover on screen.
Do not rotate it more than once. The wiring cables within the camera
may be twisted and broken, damaging the camera.
DC iris adjustment
volume
Line phase
adjustment volume
360º Pan
360º Rotation
180º Tilt
EG-7
Adjusting the view angle and focus
Move the lever to adjust focus and angle of view.
Installation and adjustment complete
Attach the inner cover.
1
After aligning the inner cover as
shown in the right fi gure, push it until
you hear a click.
Attach the dome cover to the
2
dome base.
After aligning the groove between
the dome cover and the dome base,
push the cover until you hear a click.
View angle
adjustment lever
Focus adjustment
lever