- ページ 5

冷蔵庫 Avantco 178A23RHCのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Avantco 178A23RHC 9 ページ。 Reach-in refrigerators & freezers
Avantco 178A23RHC にも: ユーザーマニュアル (8 ページ)

Avantco 178A23RHC ユーザーマニュアル

Temperature Controls

Adjusting the Temperature

• Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food safety and
should require no adjustments.
• Refrigerators are set to cycle between a minimum temperature of 33°F and a maximum temperature of 40°F.
• Freezers are set to cycle between a minimum temperature of -5°F and a maximum temperature of 2°F.
• Adjusting the temperature changes the minimum temperature at which your unit will run. Your unit will not run
constantly at this setting. To change it, follow these instructions:
Digital Control Units
1. Hold "SET" for 1 second. The display will flash the
current minimum temperature.
2. Use the arrow buttons to adjust the minimum
temperature you'd like the unit to run at.
3. Press "SET" again to save your settings.
Always remember to calculate the differential if you
change the minimum temperature setting. The cabinet
temperature will fluctuate up to 7°F over your set
minimum temperature as the compressor runs and
shuts off. Setting the temperature too high will result
in unsafe maximum temperatures and possible health
code violations.

Operation

Defrost System

Automatic Defrost Cycle
• Refrigerator coils are kept below the freezing point (32°F).
• During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil.
This air circulation raises the coil temperature above the freezing point, melting any accumulated frost.
• Run-off water is drained into the evaporator pan and evaporated.
• Automatic defrost timers initiate at pre-set intervals and for a pre-determined duration.
User Manual
Reach-In Refrigerators & Freezers
Freezers (older models)
Refrigerators & Newer Freezers
www.AvantcoRefrigeration.com
5