5. Remove vent knockouts depending on your installation
requirements.
A. Round vent knockout
B. Top rectangular vent knockout
C. Rear rectangular vent knockout
Round vent system installations - Remove top rectangular
and round vent knockouts.
Rectangular vent system installations - For roof
installations, remove the top rectangular vent knockout. For
wall installations, remove the rear rectangular vent knockout.
Non-vent (recirculating) installations - Do not remove any
knockouts.
6. Install 7" (17.8 cm) round vent mounting plate or 3¹⁄₄" x 10"
(8.3 x 25.4 cm) vent damper, depending on your vent system
installation. Attach to range hood with 3.5 x 9.5 mm screws
provided.
NOTE: An optional 7" (17.8 cm) round damper is also
available as an accessory. For information on ordering, see
the "Accessories" section.
A. 7" (17.8 cm) round damper
(see "Accessories" section)
B. 3.5 x 9.5 mm screws
C. 7" (17.8 cm) round vent mounting plate
D. Round vent knockout
E. Rectangular vent knockout
A
B
C
A
B
C
D
E
NOTE: The 7" (17.8 cm) round vent mounting plate and
3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent connector can
be installed up to 1" (2.5 cm) on either side of the hood
center to accommodate off center ductwork.
A
D
B
A. Vertical connector
B. 3.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal connector
If a vent damper is installed with a wall cap with damper,
check that they do not interfere with each other. Remove
the vent connector damper flap if they interfere.
Non-vented (recirculating) installations - No vent
attachments. Removal of the recirculation cover plate is
required. Remove the two screws from the recirculation
cover plate and remove.
A. Screws
B. Recirculation cover plate
B
C
A
B
11