5 Video output connector
Connected to the TV monitor with a coaxial
cable.
6 Power input terminal
(when using 12 V DC/24 V AC)
This model can use 24 V AC and 12 V DC.
:
Use only with a 24 V AC power supply
marked class 2 or +12 V DC power supply.
12V DC connection
When connecting to a terminal
When connecting a cable to a power cable
terminal (AWG16-24), peel off the cable by
11 mm from the end.
11 mm
Power cable (when using 230V AC)
AC Power Cord : Use AC230 V, 50Hz.
(ZC-YX270PE, ZC-NX270PE,
ZC-YXW270PE, ZC-NXW270PE)
Power plug
:
Use only with a 230V AC.
24V AC connection
B/W-FIX
TERM
OFF A+ A- B+ B-
GND
ON
VIDEO
AC230V
AC230V cable
7 Auto-iris output connector
For connecting the cable of an auto-iris lens,
the pin assignment is as shown below. (While
using the auto-iris lens, set the Auto-iris
Mode switch (3) to "DC" or "VIDEO"
depending on the type of lens used.)
No.
DC
1
CONTROL-
2
CONTROL+
3
DRIVE+
4
DRIVE-
8 B/W Fix terminal/Mode Selection terminal
This terminal can be used as a B/W Fix
terminal and also as a Mode Selection
terminal that enables the dynamic switching
of OSD settings. The mode selection setting
needs to be adjusted beforehand on the
OSD setting screen. The picture mode can
be fixed at B/W by shorting the two contacts
on the B/W Fix terminal. (See the back side
of the camera on page 3.) Fixing the picture
mode at B/W can prevent the picture from
having a phenomenon in which continuous
switching occurs between the color mode
and B/W mode under infrared illumination.
The Mode Selection terminal allows switching
between Profile 1/Profile 2 selected on the
OSD screen.
When using infrared illumination, make sure
to adjust the focal point of the lens in color
mode.
If excessive infrared illumination causes the
phenomenon above, set the picture mode at
B/W using the BW Fix terminal.
EG-6
VIDEO
+9.4V (max. 50 mA)
N. C.
VIDEO
GND