7. Using 2 people, lift range hood into final position, feeding
electrical wire through wiring opening. Position the range
hood so that the large end of the keyhole slots are over the
screws. Then push the hood toward the wall so that the
screws are in the neck of the slots. Tighten mounting screws
to cabinet, making sure mounting screws are in narrow neck
of slots.
8. Check that the damper, if used, rotates up and down freely.
9. Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
_,.,.,,_£ S(,,_.,0t'
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect
ground wire to green ground screw in
terminaJ box.
Failure to do so can result in death, fire, or
electrical
shock.
Install 75-watt
(max.) Incandescent
Light Bulb
1. Squeeze the plastic lens cover and remove it from the hood.
B
A
/
A. Light bulb socket
B. Lens cover
2. Screw light bulb into socket.
3. Replace lens cover by squeezing cover and inserting tabs
into slots.
Check
Range
Hood Operation
1. Check light operation only by pressing light button.
2. Check operation of fan by pressing button to Hi and Lo
positions.
3. If the range hood does not operate, check to see whether a
circuit breaker has tripped or a house fuse has blown.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
Direct Wire Installation
1=
4=
5.
6.
Connect the white wire of the home power supply with the
white wire in the range hood using a UL listed twist-on
connector.
............
i.................
i
E
A. White wires
B. Black wires
C. Green ground screw
D. Ground wire
E. UL fisted or CSA approved strain relief
2. Connect the black wire of the home power supply with the
black wire in the range hood using a UL listed twist-on
connector.
3. Connect ground wire (green or bare) of home power supply to
the green ground screw in the terminal box.
Tighten strain relief screws.
Install the terminal box cover.
Reconnect power.