- ページ 13

キッチン家電 Avantco 178UDD72HCのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Avantco 178UDD72HC 19 ページ。 Beer dispensers
Avantco 178UDD72HC にも: ユーザーマニュアル (19 ページ), ユーザーマニュアル (19 ページ)

Avantco 178UDD72HC ユーザーマニュアル
Changing C02 Cylinder
Follow these instructions at ALL times when you replace a CO2 gas cylinder.
1.
Close cylinder at A.
2. Remove tap D from keg. Pull pressure release ring on body of tap to release pressure remaining in line (do
not close C).
3. Remove or loosen regulator key B by turning counter clockwise.
4. Remove regulator from used cilinder at E.
5. Remove dust cap from new gas cylinder at E and clear dust from outlet by opening and closing valve A
quickly using appropriate wrench.
6. Attach regulator to new cylinder at E (use new fiber/plastic washer, if required).
7.
Open valve A all the way.
8. Close valve C.
9. Adjust regulator key B by turning clockwise to set pressure (check setting by opening C and pulling and
releasing the ring F on the pressure release valve on the body of the tap).
10. Tap keg at D with valve C open.
NOTE: DO NOT drop cylinders. DO NOT lay cylinders flat. It requires 1/2 lb. of CO2 to dispense 1/2 barrel of
beer at 38°F with 15 lbs. of pressure on barrel.

Pressure Adjustment on CO2 Regulator

Increasing Pressure:
1.
Close regulator shut-off C.
2. Turn regulator key B clockwise and make setting.
3. Tap gauge for accurate reading.
4. Open regulator shut-off C and draw beer.
Decreasing Pressure:
1.
Close regulator shut-off C.
2. Untap keg at D and activate tap handle to bleed line.
Leave in open position.
3. Slowly open regulator shut-off C and simultaneously
turn regulator key counter-clockwise to zero reading.
4. Close regulator shut-off C and set pressure by turning
regulator key clockwise. Check setting by
opening and closing valve C.
5. Close tap head D (put in OFF position).
6. Tap keg at D and open regulator shut-off C.
User Manual
Beer Dispensers
www.AvantcoRefrigeration.com
13