Changing CO
Follow these instructions at ALL times when you replace a CO
1 . Close cylinder at A .
2 . Remove tap D from keg . Pull pressure release ring on body of tap to release pressure
remaining in line . (do not close C)
3 . Remove or loosen regulator key B by turning counter clockwise .
4 . Remove regulator from used cilinder at E .
5 . Remove dust cap from new gas cylinder at E and clear dust from outlet by opening and closing
valve A quickly using appropriate wrench .
6 . Attach regulator to new cylinder at E . (use new fiber/plastic washer, if required) .
7 . Open valve A all the way .
8 . Close valve C .
9 . Adjust regulator key B by turning clockwise to set pressure . (check setting by opening C
and pulling and releasing the ring F on the pressure release valve on the body of the tap) .
10 . Tap keg at D with valve C open .
Note: DO NOT drop cylinders. DO NOT lay cylinders flat.
It requires 1/2 lb. of CO
with 15 lbs. of pressure on barrel.
Pressure Adjustment on CO
Increasing Pressure:
1 . Close regulator shut-off C .
2 . Turn regulator key B clockwise and make setting .
3 . Tap gauge for accurate reading .
4 . Open regulator shut-off C and draw beer .
Decreasing Pressure:
1 . Close regulator shut-off C .
2 . Untap keg at D and activate tap handle to
bleed line . Leave in open position .
3 . Slowly open regulator shut-off C and
simultaneously turn regulator key
counter-clockwise to zero reading .
4 . Close regulator shut-off C and set pressure by
turning regulator key clockwise . Check setting
by opening and closing valve C .
5 . Close tap head D . (put in OFF position)
6 . Tap keg at D and open regulator shut-off C .
Gas Cylinder
2
to dispense 1/2 barrel of beer at 38°F
2
gas cylinder .
2
Regulator
2
(May vary based on regulator design)