- ページ 8
マーチャンダイザー FRIGOGLASS Flex 60 HCのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。FRIGOGLASS Flex 60 HC 13 ページ。
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
The ICM does not
work.
The cooler does not
cool.
Models Flex 35 HC, Flex 45 HC and Flex 60 HC are equipped with
HC refrigerant. All service operations on cooling mechanism &
gas charging should be performed in a well ventilated
environment or in open air. Do not smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door of the cooler closed during cooling mechanism
maintenance. The appliance will not stand stable when the
compressor is disassembled. If the compressor needs to be
replaced, use adequate support to stabilize the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
POSSIBLE REASONS
Power cord not plugged in.
No power supply at the socket.
The ICM has recently been reloaded
with warm products. Please note
that it takes some time to cool warm
products.
The ICM is loaded in such a way
that the air circulation in the interior
is getting blocked.
The door does not seal properly.
Leakage in the cooling system.
HANDLING
Plug it in.
Check the outlet fuse.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Repair the leakage (this type of repair
should be performed by an authorized
technician).
ENG
8