EWS-102 CONTROL UNIT
To begin the system
setup, press the
buttons together.
Enter the system setup menu.
Select the first menu item.
CAP
AL 1
AL 1
AL 2
AL 3
hyst
dLy
diSP
FIL
bEEP
5rES
Firmware 2.5 Rev 1 subject to alteration
and
CAL
SYST
CAP indicates the elevator maximum capacity. To view the current value press
AL 1 is the load value to trigger Alarm Relay 1. To view the current value press
AL 2 is the load value to trigger Alarm Relay 2. To view the current value press
AL 3 is similar to Alarms 1 & 2 but allows negative values to be entered. When editing the
most significant digit, instead of rolling over from 9 to 0 it included the minus sign option.
Defines the value by which the load in the lift has to drop to reset the instrument,
once the alarm has been triggered.
Defines the time from the control signal input is activated and the car load is stored.
Default =2, the available settings are: 0 = 0sec, 1 = 0.5sec, .....7 = 3.5sec.
Op�on for turning the display on or off when the li� is moving, the door close signal
ac�vates. To change the setting, press
The filter value determines the update rate and damping factor. The available settings are:
0 = 0.4sec, 1 = 0.8sec, 2 = 1.2sec, 3 = 1.6sec.
An internal sounder beeps when an overload alarm is triggered or when the keypad is pressed.
To change the setting, press
Op�on to turn the systems reset func�on on or off. Leave OFF during system set up and zero and
load calibra�on. Select ON a�er calibra�on and before entering the li� into service.
To change the setting, press
Save and return to normal operation by pressing
The system setup menu allows you to set and adjust various
system parameters.
Naviga�on
Use the
bu�on to step through the menu items.
Press
to view the menu item
Edi�ng Values
When a value is displayed, use
edit (selected digit flashes) and use
values for that digit.
Press
to save a change. The system will revert to the
opera�onal display a�er approx. 10 seconds. Alterna�vely,
return to the opera�onal display by pressing
Notes
To calibrate the EWS 102, a link must be fi�ed to the control
signal input terminals
Un�l a sensor is connected, the EWS will display Err6
preven�ng access to the system setup and calibra�on menus
For further informa�on refer to EWS 102 User Manual
and use
To toggle between On and OFF.
and use
To toggle beteween On and OFF.
and use
To toggle beteween On and OFF.
twice
www.garan.co.uk
SYSTEM SETUP
to select the digit to
to step through the
twice
Page 1