INSTALLATION
Selecting compressor
4
3
2
2
1
0
10
20
►
1. Nailing frequency (times/min) 2. Compressor air
output per minute (CFM (ft
PSIG) 4. 0.66 MPa (95 PSIG) 5. 0.49 MPa (70
PSIG)
The air compressor must comply with the requirements
of ANSI B19.3.
Select a compressor that has ample pressure and air
output to assure cost-efficient operation. The graph
shows the relation between nailing frequency,
applicable pressure and compressor air output. Thus,
for example, if nailing takes place at a rate of
approximately 60 times per minute at a compression
of 0.66 MPa (95 PSIG), a compressor with an air
output over 3.0 CFM ( ft
Pressure regulators must be used to limit air pressure to
the rated pressure of the tool where air supply pressure
exceeds the tool's rated pressure. Failure to do so may
result in serious injury to tool operator or persons in the
vicinity.
Selecting air hose
CAUTION:
Low air output of the compressor,
or a long or smaller diameter air hose in relation
to the nailing frequency may cause a decrease in
the driving capability of the tool.
30
40
50
1
3
/min.)) 3. 0.83 MPa (120
3
/minute) is required.
Use an air hose as large and as short as possible to
assure continuous, efficient nailing operation.
With an air pressure of 0.49 MPa (70 PSIG), an air hose
with an internal diameter of over 6.5 mm (1/4") and a
length of less than 20 m (66 ft.) is recommended when
the interval between each nailing is 0.5 seconds. Air
3
supply hoses shall have a minimum working pressure
rating of 1.03 MPa (150 PSIG) or 150 percent of the
4
maximum pressure produced in the system whichever
is higher.
5
Lubrication
60
To insure maximum performance, install an air set (oiler,
regulator, air filter) as close as possible to the tool.
Adjust the oiler so that one drop of oil will be provided
for every 30 nails.
When an air set is not used, oil the tool with pneumatic
tool oil by placing 2 (two) or 3 (three) drops into the air
fitting. This should be done before and after use. For
proper lubrication, the tool must be fired a couple of
times after pneumatic tool oil is introduced.
FUNCTIONAL
DESCRIPTION
CAUTION:
function on the tool, always release the trigger
and disconnect the air hose from the tool.
5 ENGLISH
Before adjusting or checking