4. Using the final measurement from Step 3, measure from the
floor up and mark a horizontal line on the wall where a wall
stud is located.
A
D
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D. Anti-tip bracket
5. Position top of anti-tip bracket at line marked in Step 4 and
mark holes. Drill two
" holes at the positions marked on the
wall. Use screws provided to fasten anti-tip bracket to wall.
Anti-tip bracket must be mounted securely to stud in wall
behind the range. Depending on thickness of the wall, longer
screws may be required. Longer screws are available from
your local hardware store.

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This range must be connected to a grounded, metallic permanent
wiring system or a ground connector should be connected to the
ground terminal or wire lead on the range.
This range is manufactured with a frame connected, green or
bare ground wire. Connect the range cable to the junction box
through the UL listed or CSA approved conduit connector.
10
B
C
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire direct
A fused
disconnect or
circuit breaker
box
5"
(12.7 cm)
3-wire direct
A fused
disconnect or
circuit breaker
box
3 "
(8.9 cm)
4-Wire Cable from Power Supply
IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire.
A
B
C
D
A. Cable from power supply
B. Red wires
C. Green (or bare) ground wires
D. 4-Wire cable from range
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible armored cable from the range to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. Connect the two black wires together using the UL listed wire
nuts.
6. Separate the factory-crimped bare and white range wires.
7. Connect the two white wires together using the UL listed wire
nuts.
8. Connect the green or bare ground wire from the range cable
to the green or bare grounded wire (in the junction box) using
the UL listed wire nuts.
9. Install junction box cover.
10. Reconnect power.
Go to Section:
4-Wire Cable from
Power Supply
3-Wire Cable from
Power Supply
E
F
G
H
I
E. Junction box
F. White wires
G. UL listed wire nuts
H. Black wires
I. UL listed or CSA approved
conduit connector