DVR HIKVISION MD5043SDのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。HIKVISION MD5043SD 20 ページ。 Mobile video recorder

HIKVISION MD5043SD クイック・スタート・マニュアル
Mobile Video Recorder (-SD) Quick Start Guide
Result
Figure 2-4 Scheduled Shutdown
What to do next
Configure parameters of the function. Refer to User Manual for details.

2.2 Alarm Input Connection

The device adopts the high/low-level electrical signals triggering (high level: 6 to 36 VDC; low level:
0 to 5 VDC) to realize alarm input. And in order to avoid error report caused by voltage fluctuation,
no alarm will be triggered by voltage ranging of 5 to 6 VDC.
Figure 2-5 Alarm Input Connection

2.3 Sensor-In Wiring

Steps
1. Connect the delivered extension cable to I/O interface.
2. Connect the automobile braking, reversing, left-turn, and right-turn signals to sensor-in
interface.