コントローラー Jandy Infinite WaterColors IWCP50W100のPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。Jandy Infinite WaterColors IWCP50W100 12 ページ。 Led lighting
Jandy Infinite WaterColors IWCP50W100 にも: 設置および操作マニュアル (12 ページ), マニュアル (2 ページ)
ENGLISH
Section 2. Product Overview
Model #
Light Size
IWCP50W100
Large
IWCP50W200
Large
IWCS25W100
Small
IWCS25W200
Small
IWCPSKIT100*
Large and
Small
Section 3. New Construction
Installation
The Jandy Infinite WaterColors Pool & Spa LED Lights
are designed to be powered and operated with the Jandy
Infinite WaterColors LED Light Controller. Follow all
installation and operating instructions.
WARNING
Risk of Electrical Shock or Electrocution.
This underwater light must be installed by a licensed
or certified electrician or a qualified pool serviceman
in accordance with the National Electrical Code and
all applicable local codes and ordinances. Improper
installation will create an electrical hazard, which could
result in death or serious injury to pool or spa users,
installers or others due to electrical shock, and may
also cause damage to property.
Always disconnect the power to the color light at the
circuit breaker before installing or servicing the light.
Failure to do so could result in death or serious injury
to serviceman, pool or spa users or others due to
electrical shock.
3.1
Preparing the Light Fixture for
Installation
NOTE
The electrician must complete preparatory steps
before light fixture is installed. See Figure 1.
Ensure that the pool meets the requirements of the
current National Electrical Code
and ordinances. A licensed or certified electrician must
install the electrical system to meet or exceed those
requirements before the underwater light is installed.
Some of the requirements of the National Electrical
Code, which the pool electrical systems must meet,
are as follows:
Page 4
Jandy
Infinite WaterColors
®
Voltage
Watts
14 VAC
50W
14 VAC
50W
14 VAC
25W
14 VAC
25W
14 VAC
50W (Large)
25W (Small)
*Includes Infinite WaterColors LED Light Controller
and all local codes
®
|
Pool & Spa LED Lights
Installation and Operation Manual
™
Cord
Amps
Length
3.6 A
100 feet
3.6 A
200 feet
1.8 A
100 feet
1.8 A
200 feet
3.6 A (Large),
100 feet
1.8 A (Small)
WARNING
To minimize risk of Electrical shock or electrocution,
which could result in injury or death, for supply
connection of low-voltage lights use only the Jandy
Infinite WaterColors LED Light Controller which is an
isolating low voltage power supply, evaluated and
listed by a Nationally Recognized Testing Laboratory
(NRTL) intended for use with submersible luminaires
for swimming pool use.
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION,which
could result in serious injury or death. A Ground
Fault Circuit Interrupter (GFCI, in Canada: Class A
type) should be used if required by the transformer
manufacturer or if required by the local applicable
code and/or Authority Having Jurisdiction (AHJ). When
a GFCI is used, the conductors on the load side of
the GFCI circuit shall not occupy conduit, boxes, or
enclosures containing other conductors unless the
additional conductors are also protected by a GFCI.
Refer to local codes for complete details. When a GFCI
is used, the conductors on the load side of the GFCI
circuit shall not occupy conduit, boxes, or enclosures
containing other conductors unless additional
conductors are also protected by a GFCI. Test the
GFCI on a routine basis.
Refer to local codes for complete details.
# of
Face Ring
Lights
Material
Included
Stainless Steel
1
Stainless Steel
1
Stainless Steel
1
Stainless Steel
1
Stainless Steel
1 Pool