Cabinet Dimensions
- Double Ovens
Double Ovens Installed in Cabinet
B
T
E
C
A. 30" (76.2 cm) min. cabinet width
B. 1" (2.5 cm) top of cutout to bottom of upper
cabinet door
C. 14 _" (37.5 cm) bottom of cutout to floor
D. 28½" (72.4 cm) cutout width
E. 1 ½" (3.8 cm) min. bottom of cutout to top of
cabinet door
F. 49_"
(126.4 cm) min. cutout height
Cabinet Side View - Single or Double Oven
E--.
D
jC
A. 24" (61.0 cm) min. cutout depth
B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven
E, Cabinet
For best results, do not install the water filtration system outside,
or in extreme hot or cold temperatures.
Temperature of water
supply to the water filtration system must be between 40°F/4°C
and 100°F/38°C. Do not install on hot water supply line.
Locate the water filtration system near the cold water supply pipe
under the kitchen sink to filter cold water.
It will be necessary to drill a V2" (1.3 cm) minimum diameter hole
in the upper right or left rear corner of the side wall of the cabinet
under the sink to route the water supply tubing through to the
oven cabinet cutout.
Another V2" (1.3 cm) minimum diameter hole will need to be
drilled at the rear wall in the oven cabinet cutout.
Depending on your installation configuration,
more routing holes
may be required.
Coil enough copper tubing inside the oven cabinet to allow for
the connection to the oven to be made outside the oven cabinet
prior to setting the oven in place.
Typical Installation Configuration
NOTE: For unique installations contact a licensed plumber.
Cold water
supply
Filter
assembly
location
A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate the steam feature. In
Massachusetts,
plumbing code 248 CMR 3.00 and 10.00 must
be followed. If you have questions about your water pressure call
a licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT:
The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the oven
needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 psi (276 kPa).
If the water pressure to the reverse osmosis system is less than
40 psi (276 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If you have questions about your water pressure, call a licensed,
qualified plumber.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance
with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance
with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-1atest edition, and
all local codes and ordinances.