- ページ 17

照明器具 Jandy Pro Series K-2000のPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。Jandy Pro Series K-2000 20 ページ。 Electronic water leveler

Jandy Pro Series Levolor
II Electronic Water Leveler
®
Models K-2000
5.2.2 Simulate Fill Valve and Activate
Pump
NOTE You have simulated a low water condition by
following Step 2.b. in Section 5.2.1.
1.
Twist the yellow wire and the yellow wire with
the red stripe together to simulate a high water
condition in the vanishing edge catch basin.
2.
Remove the three (3) screws from the upper cover
plate and lift the upper cover plate off the control
box.
3.
Verify that dip switches S2-S10 are set to the OFF
position and that dip switch S1 is set to ON. See
Figure 14, page 15.
4.
Verify that jumpers 1 and 2 are installed on the
control PCB. See Figure 13, page 14.
5.
Replace the upper cover plate, making sure that
the five (5) LEDs line up with the plastic lenses
on the cover. Attach the upper cover plate to the
control box using three (3) screws. Do not over
tighten.
6.
Restore power to the control box and observe the
operation. The control box is working if steps
6 a - e and the steps in Section 5.2.3 and
Section 5.2.4 occur.
a.
The Power light turns green.
b.
The Sensor light turns yellow.
c.
The High Water Sensor light turns yellow.
d.
After 20 seconds, the Fill light turns green
and you can measure 24VAC across the blue
wires with an AC volt meter.
e.
After 2 ½ minutes, the High Water Pump
light turns green and you can measure
24VDC across the red and gray wires with a
DC volt meter.
|
Installation and Operation Manual
5.2.3 Simulate Water Level Full
Shut off the fill valve by simulating a water level full
condition.
1.
Twist these three (3) wires together: yellow wire,
yellow wire with blue stripe, and yellow wire with
red stripe.
2.
The Sensor light turns off immediately.
3.
After 20 seconds, the Fill light turns off.
4.
You can measure 0VAC across the blue wires with
an AC volt meter.
5.2.4 Simulate Lowering of High Water
Level in Catch Basin
Shut off the High Water Pump by simulating that the
High Water level in the vanishing edge catch basin has
lowered.
1.
Disconnect the yellow wire with the red stripe
from the yellow wire and yellow wire with the
blue stripe.
2.
The High Water Sensor light turns off
immediately.
3.
After 20 seconds, the High Water Pump light
turns off.
4.
You can measure 0VDC across the red and gray
wires with a DC volt meter.
5.2.5 Manual Valve Override
There is a manual ON/OFF lever located just below the
solenoid. If you are having a problem with the system
and want to override the electronic water Levolor, you
can manually open the valve by putting the lever in the
up position ↑ (12 o'clock) for manual filling. See
Figure 6, Manual Valve Lever, on page 9.
During normal operation, the lever must be in the
horizontal position → (3 o'clock) for controller filling.
See Figure 6, Manual Valve Lever, on page 9.
5.2.6 Troubleshooting Specific Conditions
Use the troubleshooting flow charts on the following
pages to find and fix the following problems.
- Fill Will Not Turn Off
- Fill Will Not Turn On
Page 17
ENGLISH