Tools needed
installation:
leve!
for
ratchet
Phillips
fiat-blade
/_
screwdriver
_lr_Wnduri2er or
_
_:
_,,,
'_
driver
:I
_,\
pliers ._'
_
safety
//_/?.//
//
3/16" carbide-tipped
masonry
drill bit
Parts supplied
for
installation:
anti-tip
bracket
(Bracket
must be
securely
mounted
to
sub=floor, Thickness
)lastic
of flooring
may
2
anchors
require longer
screws to anchor
the
(#10 x 1-1/2")
bracket to sub-floor,)
lectrical
requirements
Electrical
Shock Hazard
Electrically
ground range.
Failure to follow these instructions can
result in death, fire, or electrical
shock.
If codes permit and a separate
ground wire is
used, it is recommended
that a qualified
electrician determine
that the ground path is
adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are not
sure range is grounded.
Do Not have a fuse in the neutral or
ground circuit.
[_
hen a four-wire or three-wire, single-
phase, 120/240-volt, 60-Hz, AC-only,
electrical supply is available, a 50-ampere
maximum circuit protection is required, (or, if
specified on the model/serial rating plate, when a
four-wire or three-wire, single-phase 120/208-volt,
60 Hz, AC-only electrical supply is available, a 40-
ampere maximum circuit protection is required),
fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. The model/serial
rating plate is located on the oven frame behind the
drawer.
THE RANGE MUST BE CONNECTED
WITH COPPER WIRE ONLY.
Wire sizes and connections must conform
to the requirements of the National
Electrical Code, ANSI/NFPA 70 --latest
edition* or CSA Standard C22.1, Canadian
Electrical Code, Part 1 -- latest edition** and all
local codes and ordinances for the kilowatt rating of
the range.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269
** Canadian Standard Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario MgW 1R3
This range should be connected
directly to the fused disconnect or circuit
breaker box through flexible, armored or
non-metallic sheathed, copper cable (with
ground wire). Locate the junction box to allow
two to three feet of slack in the line so that the
range can be moved if servicing is ever
necessary.
Do Not cut the conduit.
A U.L-listed
conduit connector must be provided
at each end of the power supply cable (at the
range and at the junction box). Wires sizes
(COPPER WIRE ONLY) and connections must
conform with the rating of the range,
ectrical
connection
Electrical
Shock Hazard
Turn power supply off before connecting
wires.
Use 8-gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical
shock.
This range must be connected
to a grounded,
metallic,
permanent wiring system, or a
ground
connector
should
be connected
to
the ground terminal
or wire lead on the
range.
This range is manufactured with white (neutral)
power supply wire and a cabinet-connected
green ground wire twisted together.
Connect the range cable to the junction box
through a U.L.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.
A. If connecting
to a four=wire
electrical
system...
Do Not connect
the cabinet-grounding
conductor
to the neutral (white) junction
box
wire:
junction
cable from
power supply
white
red
wires
wires
bare or
green
wires
Figure 1
black
wires
cable from
conduit
range
connector
1. Disconnect
the power supply.
2. Separate the green (or bare) and white
appliance cable wires,
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together, See Figure 1.
5. Connect the green appliance cablewire to the
green ground wire in the junction box.
B. Where
local
codes
permit...
connecting the cabinet-grounding
conductor
to the neutral (white) junction box wire:
cable from
junction
power supply
box .._._
black
bare or_
1
green wire
_
"_'_- U.L.-listed
conduit
cable from
connector
Figure 2
range
Grounded
Neutral
1. Disconnect
the power supply.
2. Remove the terminal block cover.
3. Connect together 3 wires: green and white
appliance cable wires and the neutral (white)
wire in junction box.
4. Connect the two black wires together; then the
two red wires together, See Figure 2.
C. Where local codes DO NOT
permit...
connecting the cabinet-grounding
conductor
to the neutral (white) junction box wire.
Cable from
Junction
power supply
White
Red
, wires
wires
Bare
green
wires
U.L-Iisted
cable from
conduit
Figure 3
range
connector
Black wires
Grounded
Neutral
1. Disconnect
the power supply.
2. Separate the green and white appliance cable
wires.
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 3.
5. Connect the green or bare ground wire from
the appliance cable to a grounded wire in the
junction box.
Now start...
With
range in kitchen.
Put on safety glasses and gloves.
Remove shipping materials, tape and
protective film from range. Keep
cardboard bottom and shipping base under
range. Remove oven racks and parts package
from inside oven.
Take 4 cardboard
corners from the
carton. Stack one
cardboard corner
on top of another.
Repeat with the
other two
corners. Place
spacers
corners lengthwise
on the floor in back of range so corners will
support outer side edges of range as shown.
Panel B