Problem
Pump doesn't start or suddenly
stops during operation
Pump runs, but output suddenly
decreases
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.
7. TECHNICAL DATA
Rated Power
Rated power
Max. delivery capacity
Max. pressure
Max. delivery height
Max. submersion depth
Contaminated water with
particle size of max.
Power cable
Pump connection
Min. water level for operation
Weight approx. (without cable)
Max. media temperature
Mains voltage / Mains frequency
Min./max. cut-in height
Min./max. cut-out height
Sound power level L
1)
WA
Measuring process complying with:
Cut-in / Cut-out height:
The cut-in and cut-out height varies.
Only for the submersible pumps Art. 1783 / 1785:
The residual water height (flat suction down to approx.
1 mm) is only reached during manual operation with the
8
swivel feet
turned to 1 mm (see 3. OPERATION).
14
Possible Cause
Dirt particles are jammed in the
suction base.
Suction base is clogged.
Submersible pumps
aquasensor
Unit
Value 9000
(Art. 1783)
W
320
l/h
9,000
bar
0.7
m
7
m
7
mm
1
mm
5
m
10 H05RN-F
mm
5
kg
3.8
°C
35
V / Hz
230 / 50
mm
5 / 175
mm
3 / 170
dB (A)
48
EN 60335-1
1)
Remedy
v Disconnect plug and clean suction
base (see 5. MAINTENANCE).
v Disconnect plug and clean suction
base (see 5. MAINTENANCE).
Dirty water pumps
aquasensor
Value 13000
Value 8500
(Art. 1785)
(Art. 1797)
650
380
13,000
8,300
0.8
0.6
8
6
7
7
1
35
5
30
10 H07RN-F
10 H05RN-F
universal (G 1 ¹⁄₄" M) / universal nipple
5
45
5.4
4.0
35
35
230 / 50
230 / 50
5 / 210
65 / 230
3 / 205
40 / 225
55
55
Value 13000
(Art. 1799)
680
13,000
0.9
9
7
35
30
10 H07RN-F
45
5.6
35
230 / 50
70 / 265
40 / 260
55