5. Storage
Storage:
©
©
Disposal:
(in accordance with
directive 20002/96/EC)
6. Maintenance
Clean suction filter:
©
©
If there is a risk of frost, the Pressure Tank Unit must be stored
where it will not become frozen.
1. Unplug the mains connection for the
pump.
2. Turn the rotary switch
3. Unscrew the drain screw
The Pressure Tank Unit will drain down.
4. Store the pressure tank unit in a dry,
frost-free place.
Store out of the reach of children.
The unit must not be disposed of with normal household waste but
must be disposed of in accordance with local environmental
regulations.
DANGER ! Electric shock !
➔ Pull out mains plug before undertaking any maintenance.
1. The rotary switch
If necessary turn the rotary switch
©
2. If necessary, close all the shut-off devices on the intake side.
3. Unscrew and remove cover
of the filter chamber.
©
4. Draw out filter unit
vertically upwards.
©
5. Hold beaker
filter
draw out B (bayonet fitting).
6. Clean beaker
water and clean the filter
e.g. with a soft brush.
7. Refit filter again in reverse
order.
to FILL.
.
must be set to RUN.
firmly, turn
anti-clockwise A and
under running
to RUN.
©
©
©
15