- ページ 4
水ポンプ Gardena 3000/4 ecoのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gardena 3000/4 eco 17 ページ。 Pressure tank unit
Gardena 3000/4 eco にも: 取扱説明書 (10 ページ)
Warning! This unit makes an electromagnetic
field while it operates. This field may under
some con ditions interfere with active or pas-
sive medical implants. To decrease the risk of
conditions that can possibly injure or kill, we
recommend persons with medical implants to
speak with their physician and the medical
implant manufacturer before operating.
3. Initial Operation
Installing the
Pressure Tank Unit:
Fixed installation of the
Pressure Tank Unit:
3
1
14
Warning! Keep toddlers away when you
assemble the unit. Small parts can be easily
swallowed. There is also a risk that the poly-
bag can suffocate toddlers.
The installation position must be firm and dry, and permit a secure
mounting for the pressure tank unit.
v Install the Pressure Tank Unit at a safe distance from the
pumping medium.
The pump must be installed in a location with low air humidity and
sufficient ventilation in the area of the ventilation slots. It must be
at a distance of at least 5 cm from the walls. No dirt contamination
(e. g. sand or earth) may be sucked in through the ventilation slots.
v The Pressure Tank Unit can be screwed with all 4 feet
a solid surface
Alternatively, spring mounted feet (Art. 1753-00.901.00) for low
vibration and quiet running are available as accessories via the
GARDENA Service.
Install the pressure tank unit so that there is room to place
a suitably sized drainage tray under the drain screw
the unit or system to be drained.
If possible, install the unit higher than the surface of the water to
be pumped. If this is not possible, install a vacuum-resistant valve
between the unit and the suction hose, for example for cleaning
the integrated filter.
If the pump is permanently installed indoors for domestic water
supply, the Pressure Tank Unit should not be connected to the
2
domestic water pipework with rigid pipes but with flexible tubing,
to reduce noise and to avoid damage to the pump caused by
pressure blows.
If the system is being installed permanently, please fit suitable
valves on both the intake and delivery sides. This is important
e. g. for maintenance and cleaning work or if the system is being
shut down.
The connection pieces on the intake and delivery sides may
only be tightened by hand.
1
.
2
onto
3
to allow