- ページ 5

水ポンプ Gardena 5500/5 inoxのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gardena 5500/5 inox 9 ページ。 Deep well pump
Gardena 5500/5 inox にも: 取扱説明書 (9 ページ), 取扱説明書 (9 ページ), 取扱説明書 (9 ページ), 取扱説明書 (9 ページ), 取扱説明書 (10 ページ)

Gardena 5500/5 inox 取扱説明書
DANGER!
Risk of injury due to electric shock.
The product must be supplied through a residual current device (RCD) having
a rated residual operating current not exceeding 30 mA.
The pump must not be used when people are in water.
v Please contact your electrician.
The power cable of the pump must be connected to a socket which is positioned
at a height of 1.10 m (measured from ground). Take care that the power cable
leads downwards.
Data indicated on the type plate must match technical data of the mains supply.
Only use extension cables authorised in accordance with HD 516.
v Consult your qualified electrician.
v Take care that the electrical connections are made within dry area, protected
from flooding.
v Keep mains plug dry.
Protect plug and power cable from heat, oil and sharp edges.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
The power cable must not be used for mount ing or relocating the pump.
For submerging or lifting / securing the pump, please use the fastening rope.
In Austria
In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000) / 1979
§ 22 to § 2022.1. This requires that pumps used for swimming pools and garden
ponds may only be powered through an isolating trans former.
v Please ask your electrician for his advice.
In Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected
via a residual-current device.
Notes on use
v Before operation, clear the pressure line (e. g. open closed valve, closed outlet
connector etc.).
Leaking lubricants can contaminate the pumped liquid.
For Art. 1489 / 1492 only: Running dry leads to increased wear or damage and
is to be avoided.
v The pump must be immediately switched off when water fails to flow.
v Observe max. delivery height.
When connecting the pump to the water supply system, the country-specific
sanitary regulations must be observed to prevent water not of drinking water
quality being drawn back in.
v If necessary, contact your sanitary expert.
Sand and other abrasive substances cause increased wear and reduce the
pump's output. Fibres in the water can block the turbine.
During operation, the pump must always be submersed in the water up to the
minimum submersion depth (see 8. TECHNICAL DATA).
For Art. 1489 / 1492 only: Do not allow the pump to run for more than 10 min-
utes against the closed pressure side (e. g. closed valve, closed dispenser etc.).
The pump is automatically switched off on overheating by the built-in thermal
motor protector. After having cooled down, the motor automatically switches
on again (see 6. TROUBLESHOOTING).
DANGER! This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical implants.
To decrease the risk of conditions that can possibly injure or kill, we recommend
persons with medical implants to speak with their physician and the medical
implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the product.
2. ASSEMBLY
Install foot (only for use in cisterns) [ Fig. A1 ]:
Only when the pump is sited on the ground does the foot have to be
fitted to prevent the pump from taking in any sand or dirt.
1. Push the foot
1
onto the pump from below.
2. Screw the foot
1
to the pump
Connecting the hose [ Fig. A2 ]:
The 40mm (1 1/4") internal thread (Art. 1499: 33mm (1") female thread)
on the outlet of the Deep Well Pump can be converted if necessary with
the pump fitting provided
3
to a 33mm (1") external thread. The pump
can then be connected to the GARDENA Hose Connection System
and the GARDENA Fitting Art. 1723 / 1724.
1. Screw the pump fitting
3
onto the outlet of the pump and tighten it
4
manually until the washer
fits closely. In Art. 1499 the sealing ring is
integrated in the pump fitting
3
5
2. Connect pressure hose
to the relevant adapter.
2
with the two screws.
.
3. Tie the fastening rope
6
to the two eyes
For the best pumping results, connect 25 mm (1") hoses with the
GARDENA Suction Hose Fitting Art. 1724 and one hose clamp.
If you need to disconnect the hose frequently from the pump, we
recommend using the GARDENA Pump Connection Set Art. 1752
in connection with a 19 mm (3/4") hose.

3. OPERATION

Pump water [ Fig. O1 ]:
For the pump to deliver, the inlet filter of the pump must be submersed
at least 15cm in the water.
a) Without the foot, the pump must be fixed at least 50 cm above
the ground.
b) If the foot has been fitted (cistern use), the pump may be placed
on the ground.
1. Immerse pump on the fastening rope
The mains power cable must not be subjected to tension.
6
2. Secure the fastening rope
.
3. When using the pump in deep wells or shafts (from approx. 5 m deep)
8
guide the connecting cable
clips
9
.
4. Plug the power cable
8
into a mains socket.
Attention! The pump starts immediately.
For Art. 1499 only:
Bleeding:
Before putting the pump into operation or switching it on, please note:
When first put into operation, the pump takes about 60 seconds to vent
after submersion in the water.
v Put the pump into operation only after this 60-second submersion
phase.
Once the pump has been put into operation, the end of the bleed ing
operation is indicated by a jet of water exiting the bleed openings.
Automatic mode:
The pump pumps and switches off automatically as soon as no more
water is drawn. Due to the check valve, the pressure is maintained in
the hose until water is drawn via the hose. When water is drawn via the
hose (the pressure in the hose falls below 3.5 bar), the pump switches
on automatically.
Dry run protection (flow control):
The pump switches off automatically when there is no fluid pumped
(the pump operates in cycles 30 secs. on – 5 secs. off (4x). This cycle is
repeated in 1 hr, 5 hrs, 24 hrs, 24 hrs ... ). As soon as the inlet filter of
the pump is again submersed at least 15cm in the water, the pump is
ready to operate again.
Flow control:
The flow control switches off automatically as soon as no more water is
drawn. In the event of leakage on the pressure side (e. g. leaking pressure
hose or tap) switches the pump on and off at short intervals. If the pump
is switched on and off more frequently than 7 x in 2 min. (with a leakage
< 200 l/hr), the pump switches off completely. When the leakage on the
pressure side is eliminated, the pump must be unplugged and plugged in
again in order to be operational again.
Non-return valve:
The built-in non-return valve prevents the water flowing back through the
pump.
4. STORAGE
To put into storage:
The product must be stored away from children.
v Store the pump away from frost before the first frost sets in.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
7
for the fastening rope.
6
into a well or shaft.
6
along the fastening rope
using
7