2. Remove residuals according to the waste disposal laws applicable in
your area.
To check the pressure in the storage tank [ Fig. M1 ]:
Check the pressure in the reservoir tank regularly.
The pressure in the storage tank must be approx. 1.5 bar. An air pump /
tyre inflator with pressure indicator (manometer) is required to refill the air.
1. Unscrew the protective cover
2. Open all the tapping points.
The pressure side is depressurized.
3. Place the air pump /tyre inflator on the tank valve
air until the pressure display on the air pump/tyre inflator shows
approx. 1.5 bar.
4. Screw the protective cover
(13)
5. STORAGE
To put into storage [ Fig. S1 ]:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. If applicable, close all the shut-off devices on the intake side.
3. Open all the tapping points.
The pressure side is depressurized.
(6)
4. Open the screw fitting
of the filler neck
screw
(9)
.
The pump drains.
5. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
6. TROUBLESHOOTING
DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you trouble-
shoot the product.
To loosen the impeller [ Fig. T1 ]:
An impeller blocked by dirt can be freed again.
(10)
v Turn shaft of the impeller
with a screwdriver.
This will loosen the stuck impeller.
To clean the filter [ Fig. T2 ]:
If the pump does not start or stops suddenly during operation,
this may be due to a clogged filter.
1. Loosen the screw connection
(16)
2. Unscrew the filter
.
(16)
3. Clean the filter
under running water.
(16)
4. Assemble the filter
in reverse order.
Problem
Possible Cause
Pump is running, but the
Leaky or damaged suction
suction action doesn't take
hose.
place
The pump was not filled with
water.
The liquid escapes over the
hose which is connected to
the delivery side during the
suction action.
6
(13)
.
(14)
and refill with
close again.
(7)
and the water drain
(15)
.
Remedy
v Check suction line for
damage and seal so is
airtight.
v Fill the pump
(see 3. OPERATION).
v 1. Fill the pump again
(see 3. OPERATION).
2. When starting operation
hold the pressure hose
approx. 1 m vertically
above the pump, until the
suction action has taken
place.
Problem
Possible Cause
Pump is running, but the
Absolutely vacuum-resistant connection is achieved by using
suction action doesn't take
GARDENA Suction Hoses (see 8. ACCESSORIES).
place
Leaky screw fitting at the
filler neck.
Air cannot escape, since
delivery side is closed or
remaining water is in the
pressure hose.
The waiting time wasn't
observed.
Suction filter or backflow
preventer in the suction hose
clogged.
Too high suction height.
In case of any other difficulties concerning the suction action,
use GARDENA Suction Hoses with Backflow Preventer
(see 8. ACCESSORIES) and fill in the liquid to be pumped
over the filler neck before operation.
Pump does not start,
Thermal switch has turned
or stops suddenly during
the pump off because of over-
operation
heating.
No power supply to the pump.
RCD has triggered
(residual current).
Pump is not switched on.
Pump is running but the
Suction hose end is not
delivery drops suddenly
in water.
Suction filter or backflow
preventer clogged.
Leaks at suction side.
Impeller blocked.
Noise development in the
In the case of strong flows (e. g. open hose end, without connect-
hydraulic area
ing device), noise may result in the hydraulic part of the pump.
This is harmless and does not lead to damage of the pump.
The noise can be removed by lightly changing the flow (e. g. light
opening / closing of a connecting device).
Pump switches on and
Tank membrane is damaged.
off too often
Pressure in the tank is too low. v Refill the air in the storage
Leakage on the pressure side.
NOTE: For any other malfunctions please contact the GARDENA service
department. Repairs must only be done by GARDENA service departments
or specialist dealers approved by GARDENA.
7. TECHNICAL DATA
Pressure Tank Unit
Unit
Rated power
W
Mains voltage
V (AC)
Mains frequency
Hz
Max. delivery capacity
l/h
Max. pressure /
bar /
max. delivery head
m
Max. self-priming suction
m
height
Working pressure p(W)
(switch-on to switch-off
bar
pressure
Permitted internal pressure
bar
(delivery side)
Power cable
m
Weight
kg
Remedy
v Check seal (replace if neces-
sary) and tighten connection
securely (do not use pliers).
v Open shut-off valves
(e. g. nozzle) in the delivery
line, empty the delivery hose
or disconnect it from the
pump during priming.
v Switch on the pump and wait
up to 5 min.
v Clean the filter or the back
flow preventer.
v Reduce suction height.
v Clean the filter.
Observe the max. media
temperature (35 °C).
v Check fuses and electrical
plug connections.
v Disconnect the pump
and contact the GARDENA
Service.
v Push the On / Off switch
to On.
v Submerge the end of the suc-
tion hose deeper in the water.
v Clean the suction filter or
back-flow preventer.
v Eliminate leak.
v Release impeller.
v Let the tank membrane be
replaced by the GARDENA
Service.
tank.
v Eliminate leaks on the
pressure side.
Value
Value
(Art. 9020)
(Art. 9022)
600
800
230
230
50
50
3000
3600
3,5
4,0
35
40
7
7
1.5 – 2.4
1.5 – 2.8
6
6
1.5 (H07RN-F)
1.5 (H07RN-F)
10.2
13.1