- ページ 8
水ポンプ Gardena CW Pump 2000/2 Li-18のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gardena CW Pump 2000/2 Li-18 16 ページ。
(9)
1. Turn the foot
anti-clockwise and remove the foot
(bayonet lock).
(10)
2. Turn the filter
anti-clockwise and remove the filter
(bayonet lock).
(10)
3. Clean the filter
and the foot
(10)
4. Push the filter
into the pump so that the lines
are opposite.
(10)
5. Turn the filter
anti-clockwise (bayonet lock).
6. Push the foot
(9)
onto the pump so that the lines
are opposite.
7. Turn the foot clockwise (bayonet lock).
5. STORAGE
To put into storage [ Fig. S1 ]:
The product must be stored away from children.
1. Remove the battery.
2. Charge the battery.
3. Turn the pump upside down to allow residual water to
flow out.
4. Clean the pump, the battery holder, the battery and the
battery charger (see 4. MAINTENANCE).
5. To save storage space, fold in the bracket and slide the
(11)
battery holder
from above onto the intended holder
on the pump.
6. Store the pump, the battery and the battery charger in
a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal
household waste. It must be disposed of in line
with local environmental regulations.
6. TROUBLESHOOTING
DANGER! Risk of injury!
Injury when the product starts accidentally.
v Remove the battery before you troubleshoot the
product.
Problem
Pump is running,
but doesn't deliver
16
(9)
(10)
(9)
under running water.
ß
ß
/
a1
a2
ß
ß
/
a1
a3
Possible Cause
Air cannot escape, because the
pressure line is closed.
(Possible kink in the pressure hose.)
Air in suction foot.
Foot / Filter is clogged.
Water level below minimum water
level when put into operation..
The pump must not be operated without the filter
To clean the battery, the battery holder and the
battery charger:
Make sure that the surface and the contacts of the battery,
the battery holder and the battery charger always are clean
and dry before you connect the battery charger.
Do not use running water.
v Clean the contacts and the plastic parts with a soft and
dry cloth.
IMPORTANT!
Dispose of the product through or via your municipal
recycling collection centre.
Disposal of the battery:
The GARDENA battery contains lithium-ion
cells that should not be disposed of with
normal household waste at the end of its life.
IMPORTANT!
Dispose of the batteries through or via your municipal
recycling collection centre.
1. Discharge the lithium-ion cells completely
(contact the GARDENA Service).
2. Protect the contacts on the lithium-ion cells against
short circuits.
3. Dispose of the lithium-ion cells properly.
Remedy
v Open the pressure line (e. g. shut-off
valve, delivery units).
v Wait for about max. 60 seconds until
the pump has vented; if necessary,
switch off / on several times if neces-
sary. If this does not help briefly start
the pump in the water once without
the hose.
v Clean the foot / filter.
v Submerge the pump deeper.
(10)
.
Li-ion