- ページ 2

水ポンプ Gardena WP 600のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Gardena WP 600 6 ページ。 Fountain pump 12 v
Gardena WP 600 にも: 取扱説明書 (8 ページ), 取扱説明書 (7 ページ), 操作説明 (8 ページ)

Gardena WP 600 ユーザーマニュアル
GARDENA Garden Spring Pump
WP 600 / WP 1200 / WP 1800
Welcome to the Garden of GARDENA ...
This is the translation of the original German User's Manual.
Please read the User's Manual carefully and comply with them.
Use this User's Manual to familiarise yourself with the pump, its
proper use and the safety instructions.
For safety reasons, children under 16 as well as persons
not familiar with this User's Manual must not use this pump.
v Keep this User's Manual in a safe place.
Contents
1. Where to use your GARDENA Garden Spring Pump. . . . . . . . . 8

2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. Storing your Fountain Pump Set . . . . . . . . . . . . . . . . . . . . . . . 10
5. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Trouble-shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9. Service / Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1. Where to use your GARDENA Fountain Pump set
Intended Use:
The GARDENA Garden Spring Pump is intended for domestic use
for supplying water to springs and gargoyles. It is not designed
for operating watering equipment and accessories or irrigation
systems. The pump can be used both indoors and outdoors.
Please note
The GARDENA Garden Spring Pump is not suitable for
continuous operation in industrial applications. Corrosive,
easily combustible, aggressive or explosive substances
(such as gasoline, petroleum or nitro thinners), or saltwater
must not be pumped, nor must foodstuffs or drinking water.
2. Safety instructions
Electrical Safety:
DANGER ! Electric shock !
v Always disconnect the pump
from the mains before under-
taking any work on it.
The pump should be operated via a residual
current device with a residual current rating of
30 mA (DIN VDE 0100-702 and 0100-738). The
pump must be placed on solid, even ground.
8
v Please ask your electrician for his advice.
Mains power cables should not have a smaller
cross-section than a rubber sheathed cable
of the designation H05 RN-F3G0,75.
Extension cables must meet the requirements
of DIN VDE 0620. Check line voltage.
Data indicated on the type plate must match
technical data of the mains supply.
Please unplug the pump after operation and
before carrying out any maintenance works.
The pump must not be operated when there
are people in the water.
Swimming pools and garden ponds should
be designed according to international and
national design regulations.
v Please consult a professional electrician.
Before operating the pump, look to see if there
is any damage to the pump (esp. regarding
power cable and plug).
The connection cable of the pump cannot be
replaced. If the cable is damaged the pump
must be scrapped.
Do not use the power cable to carry the pump
or to pull the plug out of the socket.
3. Initial Operation
Commissioning the pump:
1. Screw the stepped nipple
2. Connect the stepped nipple
a hose (
2
1
3. Install the pump at ground level so that the filter housing
standing in water to at least half its height.
3
4. Insert the pump plug into a mains socket.
Caution: The pump will start immediately.
5. Use the flow control
4
spring / gargoyle.
Commissioning the pump if
If the pump is installed out of water, the filter housing
it is installed out of water:
be taken off.
1. Pull off the filter housing
2. Turn the pump inlet
3
5
7
motor housing
2
3. Depending on the pumping application, the pump inlet can
be rotated in 90° steps. Twist the pump inlet
again press it vertically on to motor housing
clockwise (see 5. Cleaning).
4. Screw stepped nipples
pump outlet
6
5. Connect the pump inlet
1
(
" or
2
han the pump inlet
6. Connect the pump outlet
1
hose (
5
2
7. Fill the hose to the pump inlet
8. Insert the pump plug into a mains socket.
Caution: The pump will start immediately.
4
9. Use the flow control
spring.
Protect the power cable from heat, oil and
sharp edges.
User instructions:
Never let the pump run dry; running dry
generates heat and will damage the pump.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
1
on to the pump outlet
1
to the spring / gargoyle with
1
3
" or
").
2
4
4
to set the desired water flow for the
3
.
5
anticlockwise and pull it vertically off the
6
(bayonet socket).
5
accordingly,
6
and tighten it
7
5
on to the pump inlet
and
2
.
5
to the water reservoir with a hose
3
"). The level in the water reservoir must be highert-
4
5
.
2
to the spring / gargoyle with a
3
" or
").
2
4
5
with water.
4
to set the desired water flow for the
2
.
3
is
3
must
9