- ページ 5

芝生とガーデン用品 Gardena 1820のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gardena 1820 10 ページ。 Water timer electronic t14 e
Gardena 1820 にも: 取扱説明書 (9 ページ), 取扱説明書 (16 ページ), 取扱説明書 (15 ページ)

Gardena 1820 取扱説明書
You can start or end the watering prematurely at any time by pressing the
man. key. The watering time is then 30 minutes.
Read / Change Program
To check the data, you can repeatedly press the O.K. key to run through
the program levels. The levels are selected and checked consecutively.
This does not interrupt the current program cycle.
To change the data, proceed as described above.
Program Overview
Program
Cycle
number
00
No program active
01
6 hours (4 times daily)
02
12 hours (twice daily)
03
12 hours (twice daily)
04
24 hours (once a day)
05
24 hours (once a day)
06
24 hours (once a day)
07
24 hours (once a day)
08
2 days
09
2 days
10
2 days
11
3 days
12
3 days
13
7 days
14
7 days
Manual, programming-independent On / Off (man.)
Before and after entering data, you can operate the GARDENA Water
Timer electronic T 14 e manually, independent of the programmed data.
To do this, press the man. key.
Press the MAN key once to activate watering for a maximum of 30 minutes
(LCD : On). Press the man. key again to end watering.
8
Duration
3 minutes
3 minutes
15 minutes
3 minutes
5 minutes
30 minutes
1 hour
5 minutes
30 minutes
1 hour
30 minutes
1 hour
1 hour
2 hours

7. Changing the Battery

To ensure the Water Timer runs safely, only a 9 V alkali-
A
manganese battery (alkaline) type IEC 6LR61 must be used.
If the battery voltage falls below a
certain level the Batt. indicator appears.
It is possible to initiate watering manually
28 . . 88
·
Batt.
even if the battery capacity is too low
·
3
On
(valve no longer opens), but programmed
·
Off
watering times, however, are not initiated.
Even if the battery capacity is too low to run a program, if the valve is
open it will be closed.
The battery voltage is tested during the opening pulse. In this way you
can test the capability of the battery at any time. To do this, simply
press the On / Off-man. key. If the valve opens and the Batt. indicator does
not appear then the battery does not have to be changed.
Previously set data is lost when replacing the battery.
A
Program the Water Timer subsequently again.
For notes on changing the battery see "Inserting the Battery".
8. Notes on Safety and Operation
The minimum water output to ensure that the Water Computer
.
functions correctly is 20 - 30 l / h.
For example, at least 10 x 2-litre Drip Heads are required to
control the Micro-Drip-System.
To prevent water penetrating the battery compartment the Water
.
Timer must only be mounted in a perpendicular position with
the sleeve nut pointing upwards.
Program the Water Timer with the tap turned off. In this way
.
you can avoid getting wet when trying out the manual On / Off
function. You can remove the control unit from the housing to
program the Water Timer.
The Water Timer must only be used outdoors.
.
Warning ! The Water Timer must not be used indoors.
The Water Timer must be stored in a dry place away from frost
.
before the frosty season begins.
The max. temperature for the water flow is 40 °C.
.
9