- ページ 7

灌漑システム Gardena AquaContour automatic 1559のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gardena AquaContour automatic 1559 13 ページ。 Large-area pop-up irrigation
Gardena AquaContour automatic 1559 にも: 取扱説明書 (12 ページ), 取扱説明書 (13 ページ)

Gardena AquaContour automatic 1559 取扱説明書

Clean nozzles :

B
Clean protective panel of
solar cell :

8. Troubleshooting

Fault
Irrigation width smaller than
on initial start-up
Watering pattern uneven
Auto and Set LED flashing
simultaneously
16
If the watering pattern is no longer even, the nozzles can be
cleaned using the cleaning needle provided.
A
1. Open both locks
2. Turn the cleaning needle
(e.g. with a coin) anticlockwise
through 180° 1 and pull out
carefully 2 (bayonet coupling).
D
3. Clean nozzles
needle
4. Refit cleaning needle
reverse order.
5. Close cover
A
locks
To make sure that the rechargeable battery is always sufficiently
charged, the protective panel of the solar cell has to be cleaned
if soiled.
No caustic / abrasive cleaning agents or hard objects should
be used.
v Clean protective panel of solar cell with a damp cloth.
Possible cause
Dirt filter soiled.
Tap not opened sufficiently.
Water pressure too low.
Rechargeable batteries almost
flat (Auto and Set LED flashing) /
Protective panel of solar cells
soiled.
Large-area pop-up irrigation
is in energy-saving mode
(4 weeks without energy
supply or operation).
Irrigation range is programmed
incorrectly.
Nozzles soiled.
Nozzle head soiled.
Nozzle head damaged.
Rechargeable batteries almost
discharged.
A
and raise the cover
D
E
with cleaning
D
.
D
in
B
and both
.
B
.
E
Remedy
v Clean dirt filter.
v Open tap further.
v Increase water pressure /
water supply.
v Ensure solar cells are
exposed to sufficient
sunlight / clean protective
panel. If the rechargeable
battery is almost flat, the
range is reduced to the
min. level.
v Press OK button.
v Reprogramme irrigation
range.
v Clean nozzles.
v Clean nozzle head.
v Contact GARDENA Service.
v Ensure solar cell is exposed
to sufficient sunlight.
D