- ページ 7
ドリル Makita 6305のPDF 技術情報をオンラインで閲覧またはダウンロードできます。Makita 6305 8 ページ。 13mm (1/2")
Makita 6305 にも: 仕様 (2 ページ), 取扱説明書 (9 ページ)

High Voltage Countries and Areas
where Noise Suppression is Not Required
C
ircuit diagram
Fig. 17
Color index of lead wires' sheath
Black
White
W
iring diagram
[1] Line Filter
As illustrated in Fig. 18, route the two lead wires (white) from
Support complete through Line filter before connecting to Switch
and Terminal block.
[2] Motor Housing
Put Earth terminal in place. (See Fig. 15.)
Blue
Clear
Insulated connecter
Noise
suppressor*
Switch
Blue or White
Heat-shrink tube
Support
complete
Line filter**
Warning lamp
*Noise suppressor is not used for some countries.
**Line filter is not used for some countries.
Fig. 18
Earth terminal
Support Complete
Line filter
(to Switch and
Terminal block)
P 7 / 8