レシーバー A'OK AC202-02のPDF マニュアルをオンラインで閲覧またはダウンロードできます。A'OK AC202-02 2 ページ。
A C 2 02 - 0 2 Radio Receiver Manual
-
AC202
02
Receiver
2.Parameters
Model No.
Voltage
AC202-02
230VAC 50Hz
!
Warning
Power off before wiring
3.Wiring
signal light
IR receive head
sw1 up
sw2 stop
sw3 down
IR transmitter
AC118-01
projector
IR receive head
Manual switch and IR receive
AC112-04
AC118-01
AC104-02
Infrared control
RF Control
Temperature
Receive distance
≤ 80M
RF
-40℃~+85℃
≤ 8M
IR
Avoid static damage
program button
RF transmitter
AC104-02
Motor
power input
1.Features
Work with all A-OK tubular motor
SMT machine automatical assembly, dampproof craft
Support of IR,RF,Manualcontrol and DC12V trigger
Work with motorized projection screen, motorized
awning, roller blinds etc
AC112-04
Manual Switch
Loading Power
≤500W
Earth wire must be
connected well and correctly
up
stop
down
AC118-01
AC104-02
IR Remote Control
RF Remote control
Wiring
Motor wiring terminal
E:Earth (Green/Yellow)
N:Neutral(Blue)
L:UP /Down(Black)
R:Down/UP (Brown)
out-link projector terminal
NC:empty terminal
GND: earth wire
+ 12V:DC trigger
Manual switch wiring terminal
+5V:IR voltage
S:stop(green)
IR:IR signal
D:Down/up(black)
U:UP/DOWN(brown)
G:Neutral(BLUE)
V1.0.2
Frequency
Operation Mode
.
RF
433
92HZ
RF, IR and Manual
control, DV12V trigger
IR
38KHZ
To keep good control
range, avoid connect
metal parts
Manual pulse Switch
AC112-04
Manual switch operate instruction:
1:press up key less than1's the motor
run up,more than 1's then loose up,
the motor stop
2:press down key less 1's and motor
run down,more than 1's loose and
motor stop
Power wiring terminal
N:Neutral(Blue)
E: Earth (Yellow/Green)
L:Live(Brown)