Garmin GPSMAP 4208 - Marine GPS Receiver 取付説明書

Wiring Additional nMEA 0183 Devices

The NMEA 0183 data cable included with the GPSMAP 4000/5000 series chartplotter supports the NMEA 0183 standard, which is used to wire
various NMEA 0183-compliant devices, such as VHF radios, NMEA instruments, autopilots, or a computer.

Basic nMEA 0183 Wiring

These diagrams illustrate basic NMEA 0183 wiring used to connect your GPSMAP 4000/5000 series chartplotter to NMEA 0183-compliant
devices such as an AIS or DSC device. For more-complete information on the NMEA 0183 capabilities of the GPSMAP 4000/5000 series
chartplotter, see the section on advanced NMEA 0183 wiring
Garmin
GPSMAP 4000/5000 series
chartplotter
Garmin
GPSMAP 4000/5000 series
chartplotter
notes:
• If the NMEA 0183-compliant device has only one receiving wire (no A, B, +, or -), leave the pink wire unconnected.
• If the NMEA 0183-compliant device has only one transmitting wire (no A, B, +, or -), connect the orange/white wire to ground.
• Consult the installation instructions of your NMEA 0183-compliant device to identify the Transmit A(+) and B(-) wires and Receive A(+)
and B(-) wires.
• Use 28 AWG, shielded, twisted-pair wiring for extended runs of wire.
• Solder all connections and seal them with heat-shrink tubing.
GPSMAP 4000/5000 Series Installation Instructions
(page
16).
WIrE CoLor
FuSE
7.5 A - 42 V
rED (PoWEr)
PoWEr
BLACk (PWr GnD)
CABLE
BLACk (DAtA GnD)
>
nMEA 0183
CABLE
orAnGE/WHItE
>
>
>
Wiring to a nMEA 0183-compliant Device (AIS)
WIrE CoLor
FuSE
7.5 A - 42 V
rED (PoWEr)
PoWEr
BLACk (PWr GnD)
CABLE
BLACk (DAtA GnD)
orAnGE/WHItE
>
nMEA 0183
WHItE
CABLE
>
>
>
Wiring to a Single-ended nMEA 0183-compliant Device
-
+
BAttErY
10–35 Vdc
BLACk (PWr GnD)
BLACk (DAtA GnD)
WHItE
trAnSMIt A(+)
trAnSMIt B(-)
GrAY
PInk
-
+
BAttErY
10–35 Vdc
BLACk (PWr GnD)
BLACk (DAtA GnD)
GrAY
PInk
unConnECtED
WIrE
rED (PoWEr)
NMEA 0183-compliant
>
>
rECEIVE A(+)
>
rECEIVE B(-)
>
WIrE
rED (PoWEr)
NMEA 0183-compliant
trAnSMIt
>
rECEIVE
>
device
(AIS)
device
15