- ページ 6

水ポンプ alkitronic VELOXのPDF 操作およびメンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。alkitronic VELOX 12 ページ。 Electric hydraulic pump

alkitronic VELOX 操作およびメンテナンスマニュアル
Operation and Maintenance Manual
3.

Starting Procedure

Regularly check high pressure hoses and all
couplings as well as fittings and connections
before operating the tool. Make certain hydraulic
couplings are free of dirt before operating the tool.
Particles of dirt within the hydraulic system may
result in disturbances, faulty functions, and break
down of the motor.
Make certain the hydraulic hoses are placed in a
large radius to avoid injuries. The hoses must not
be bent, twisted, or damaged.
Note!
Check the oil level in the
showcase. The red mark
indicates the minimum
which the oil level must
not fall below.
If required, the Hydraulic
Oil (Oil grades see item
1. Technical Data) can be
refilled after removing
the Vent cap (5).
Gauge (2)
Pressure adjusting valve (3)
Vent cap (5)
Fig. 1
F
1. Attach the hydraulic hoses to the hydraulic torque wrench
and to the VELOX Hydraulic Pump (K). See connection scheme
page10, item 11.
2. Attach remote control (F). Make sure that all couplings
are fully engaged to avoid hydraulic oil shooting out and to
ensure that the hydraulic oil can flow.
Hydraulic hoses must be equipped in pairs with
alternating couplers and nipples to regulate pre-
(pressure) and reverse running to the piston or to
the pole side of the hydraulic cylinder (see page 9,
item 7. Technical hints).
An interruption on the return line will cause
2
excessive overpressure on the rod end of the
hydraulic cylinder. This may result in damage to
the tool or major injuries to the operator.
Please observe local laws and regulations when
drawing up bolt connections.
When using a hydraulic torque wrench, you must
adhere to the corresponding operation manual.
3
5
Before putting the VELOX Hydraulic Pump into
operation check the working order using a pres-
sure of max. 100 bar (procedure see item 4 and 4.1).
6
K
Fig. 2