2.5
Operation - Safety measures
The operation of (Fig. 3) Clockwise / counterclockwise rota-
tion is set via the rocker switch (3) on the pistol grip. The
compressed air is supplied through the coupling on the
compressed air hose (1).
Before connecting the air hose, set the air pres-
sure according to the machine type (see technical
characteristic data sheet). For safety reasons the
maximum operating pressure of approx. 7 bar must
not be exceeded. The consequences are increased
wear with loss of performance or even destruction
of the motor.
Never improperly block the rocker switch (3) (Fig.
3). This will prevent the functions working properly.
An uncontrollable pneumatic multiplier can cause
physical injury and / or property damage.
Manipulating and/or interfering with the motor or
the valves of the alkitronic® CL multiplier lead to a
loss of warranty.
Be careful with high pressure components. Do
not kink hose and check for damage before use.
Damaged hoses or couplings must not be used.
Defective hoses can burst and whip uncontrollably
and cause injury.
The compressed air supplied must be clean and
particle-free, without water and other residues.
Dirt on the hose couplings or aggressive materials
entering the engine via the compressed air hose
can damage the blades.
Pneumatic Torque Multiplier
2.6
Fig. 3
1
3
7
Tightening and release - Safety measures
Due to a freely rotating DMA or rotating adapter,
loose clothing, long hair, cables etc. should always
be kept out of the danger / rotation area. When
putting the device into operation, ear protection,
safety shoes and goggles must be worn.
Never leave the alkitronic® CL multiplier unattend-
ed during operation and always be ready to switch
it off. Maintain safety distance of one arm length.
Never reach between the DMA and the support
lcoation. High risk of injury through crushing!
Always fit the standard nut / connector or other
adapter completely onto the screw / nut. Improper
connection can lead to fractures due to mate-
rial overload, whereby splintering parts can cause
physical injury or even life-threatening injuries.
Due to the air-oil mixture which escapes from the
multiplier, a respirator mask must be worn, especial-
ly when working overhead or in confined spaces.
Due to the high strain of the alkitronic® pneumatic
motors, it is necessary to ensure an adequate oil
supply. Failure to do so may result in increased
wear of the slats with loss of performance or even
destruction of the motor.
The use of a maintenance unit is strongly recom-
mended in order to maintain a suitable oiled oper-
ating air (see also Service, section 3.3 Maintenance).
2-3 drops per min. is sufficient in continuous opera-
tion (see also section 4.1 Air lubrication).