Hydraulic Considerations – 2.0 L and 1.2 L Pumps
Different boats have different hydraulic considerations you must examine before mounting the pump or disconnecting any hoses.
Before starting the hydraulic installation, verify the type of hydraulic steering in your boat, and where to install the appropriate type of
pump.
If the hydraulic steering of your boat does not match the hydraulic layouts in this manual, contact Garmin Product Support.
2.0 L or 1.2 L Pump Hydraulic Layout on Single-Helm Boats (without Power Assist)
Starboard line
Return line
Port line
.0 L/1. L pump
S
R
P
Helm
Do not turn the system on until you bleed all the air from the helm, the Shadow Drive, the pump, and all the hydraulic lines.
See
page
34.
GHP 10 Marine Autopilot System Installation Instructions
Shadow Drive
(and motor)
Starboard fitting
Port fitting
Balanced cylinder
Notice
notes:
•
2.0 L/1.2 L pump (and motor):
◦
An unbalanced cylinder requires an
unbalanced valve on the pump
◦
Mount the pump horizontally if possible. Do
not mount the pump vertically with the pump
end (hydraulic connections) down.
•
Shadow Drive:
◦
Mount the Shadow Drive horizontally and as
level as possible.
◦
Install the Shadow Drive in either the port or
the starboard hydraulic steering line.
◦
Always install a length of hose between the
helm and the Shadow Drive.
Do not install the Shadow Drive directly to
◦
the helm.
◦
Install the Shadow Drive between the pump
and the helm.
Do not install the Shadow Drive between
◦
the pump and the cylinder.