- ページ 13

エアコン Fujitsu ABU30のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Fujitsu ABU30 18 ページ。 Ceiling suspension type

Fujitsu ABU30 取扱説明書

ENERGY SAVE OPERATION

Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL" (Reverse Cycle).
The air conditioner can be operated while keeping energy consumption costs down.
How To Use the ENERGY SAVE OPERATION
1
Press the START/STOP button
(if the unit is already operating, proceed to step 2).
The indoor unit's OPERATION indicator light (red) will turn on.
2
Press the MASTER CONTROL button to select the
COOL, DRY, *HEAT mode.
3
Press the ENERGY SAVE button.
ENERGY SAVE can only be used if the MASTER CONTROL button is used
to select the "COOL", "DRY" or *"HEAT".
About the ENERGY SAVE
The air conditioner saves energy costs by controlling the thermostat temperature setting.
*During Heating operation:
The thermostat temperature setting decreases by 2 F as
soon as the ENERGY SAVE button is pressed, and then de-
creases by another 2 F every thirty minutes.
In this manner, energy is saved by continuing to heat at a
thermostat temperature of 8 F less than the setting.
ENERGY SAVE setting
2 F
4 F
ENERGY
30 minutes
SAVE ON
1 hour
1 hour 30 minutes

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button on the main unit operating
control panel.
To stop operation, press the MANUAL AUTO button once again.
Set temperature
6 F
8 F
To Cancel the ENERGY SAVE:
Press the ENERGY SAVE button.
During Cooling/Dry operation:
The thermostat temperature setting increases by 2 F as soon
as the ENERGY SAVE button is pressed, and then increases
by another 2 F after one hour has passed.
In this manner, energy is saved by continuing to cool or dry
at a thermostat temperature of 4 F more than the setting.
ENERGY SAVE setting
1 hour
ENERGY
SAVE ON
2 F
CAUTION!
Do not press the MANUAL AUTO but-
ton with wet hands or pointed objects,
otherwise an electric shock or malfunc-
tion may occur.
When the air conditioner is operated
with the controls on the Main unit, it
will operate under the same mode as
the AUTO mode selected on the re-
mote control unit (see page 8).
The fan speed selected will be "AUTO"
and the thermostat setting will be
73 F.
SET
SWING
SET
SWING
TIME
TEST
ENERGY
ADJUST
RUN ACL
SAVE
4 F
Set temperature
En-13