- ページ 25

ホブ AEG 35601GのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AEG 35601G 28 ページ。 Gas hob
AEG 35601G にも: 操作および設置マニュアル (24 ページ), 操作およびインストール手順 (24 ページ)

AEG 35601G 取扱説明書

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To
do this, follow the procedure below.
1) Turn the gas tap to the MAX position and ignite.
2) Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX
several times. If the flame is unstable or is extinguished follow the procedure below.
Procedure:
1) Re-ignite the burner and set to MIN.
2) Remove the control knob.
3) To adjust, use a thin bladed
screwdriver and turn the adjustment
screw until the flame is steady and
does not extinguish, when the knob
is turned from MIN to MAX. Repeat
this procedure for all burners.
Pressure Testing
1) Remove left hand pan support and front left burner cap and crown.
2) Fit manometer tube over the injector.
3) Turn on the burner gas supply and ignite another burner supply.
The pressure reading should be nominally 20mbar and must be between 17 mbar
and 25mbar.
4) Turn off the burner supplies.
Minimum adjustment screw
25