4. BASIC OPERATIONS
3 steps to start operation
1. Press
to start or stop the operation.
2. Press
to select the operation mode.
The operation mode changes as follows.
AUTO
COOL
3. Press
to set the desired temperature.
The temperature changes by 0.5 °C increments.
Temperature setting range
Auto/Cooling/Dry
Heating
NOTES:
• In the Cooling or Dry mode, set the temperature lower than the
current room temperature.
• In the Cooling mode, the indoor unit fan may stop from time to time
to perform Fan control for energy saving that enables power-saving
operation by stopping the rotation of the indoor unit fan when the
outdoor unit is stopped.
In initial setting, this function is activated.
To deactivate the function, consult the installer or authorized service
personnel.
• In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation
when necessary.
• In the Fan mode, temperature control is not available.
Temperature unit switching
1. Press
until only the clock is displayed.
2. Press down
The current temperature unit will be displayed. (Factory setting: °C)
3. Press
to switch the temperature unit. (°C ⇔ °F)
4. Press
to fi nish the setting.
If you do not press the button for 30 seconds, the displayed
temperature unit will be set.
5. AIRFLOW SETTINGS
5.1. Fan speed setting
Press
to control the fan speed.
The fan speed changes as follows.
(Auto)
(High)
When
is selected, the fan speed depends on the operating
condition.
To increase the air cleaning effect, set the fan speed to High.
En-5
DRY
FAN
HEAT
18.0 to 30.0 °C
16.0 to 30.0 °C
for more than 5 seconds.
(Med)
(Low)
(Quiet)
5.2. Airfl ow direction setting
For details of the airfl ow ranges, refer to "Airfl ow direction
range".
Up and down airfl ow direction setting
Press
to adjust the Up and down airfl ow direction.
Left and right airfl ow direction setting
Before you adjust the left and right airfl ow direction,
make sure that the up and down airfl ow direction louver
has been stopped completely.
Adjust two knobs by hand.
Swing operation setting
Press
to start/stop the Swing operation.
NOTES: The Swing operation may stop temporarily when the indoor
unit fan is rotating at very low speed or is stopped.
Airfl ow direction range
Up and down airfl ow direction
Change by
Swing operation by
NOTES:
• Do not adjust the airfl ow direction louvers by hand.
• In the Auto or Heating mode, the airfl ow direction stay position 1 for
a while from the start of the operation.
• When indoor unit is embedded in a wall, airfl ow is fi xed to horizontal
direction 5.
Please ask the service personnel to perform the embedding in a
wall.
Vertical louver Adjustment
Adjust the vertical louver.
Move the vertical louver to adjust airflow in the direction you
prefer.
Always adjust the vertical louver when the damper is
open. Opening the damper forcibly with hands can
cause damper to malfunction.
Air outlet selection
With this function , air come out simultaneously from the upper
and lower air outlets so that the room can be cooled or heated
effectively. This function is set using the switch behind the front
grille of the Indoor unit. (This function is available in cooling and
heating operation.)
CAUTION
1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5
1
CAUTION
5