To clean the water inlet filters:
20°

10.9 Emergency drain

Because of a malfunction, the appliance
cannot drain the water.
If this occurs, do steps (1) through (6) of
'To clean the drain pump'.
If necessary, clean the pump.
Put the drainage duct back and close the
drain pump flap.
When you drain the water with the emer-
gency drain procedure, you must acti-
vate again the drain system:
1.
Put 2 litres of water in the main wash
compartment of the detergent dis-
penser.
2.
Start the programme to drain the
water.

10.10 Frost precautions

If the appliance is installed in an area
where the temperature can be less than
45°
1.
Close the water tap.
2.
Remove the water inlet hose from
the water tap.
3.
Clean the filter in the inlet hose with
a stiff brush.
4.
Remove the inlet hose behind the
appliance.
5.
Clean the filter in the valve with a
stiff brush or a towel.
6.
Install again the inlet hose. Make
sure that the couplings are tight to
prevent leakages.
7.
Open the water tap.
0 °C, remove the remaining water from
the inlet hose and the drain pump.
1.
Disconnect the mains plug from the
mains socket.
2.
Close the water tap.
3.
Remove the water inlet hose
4.
Put the two ends of the inlet hose in
a container and let the water flow
out of the hose.
5.
Empty the drain pump. Refer to the
emergency drain procedure
6.
When the drain pump is empty, in-
stall the inlet hose again.
WARNING!
Make sure that the temperature
is more than 0 °C before you use
the appliance again.