30
Without the plastic hose guide.
You can extend the drain hose
to maximum 400 mm. Contact
the service centre for the other
drain hose and the extension.
• On the edge of a sink.
• Make sure that the plastic guide can-
not move when the appliance drains.
Attach the guide to the water tap or
the wall.
• To a stand pipe with vent-hole.
Refer to the illustration. Directly into
a drain pipe at a height of not less
than 60 cm and not more than 100
cm. The end of the drain hose must
always be ventilated , i.e. the inner
diameter of the drainpipe must be
larger than the external diameter of
the drain hose.
• To a sink spigot.
Refer to the illustration. Put the drain
hose in the spigot and tighten it with
a clip. Make sure that the drain hose
makes a loop to prevent that remain-
ing particles go in the appliance from
the sink.
• Directly to a built-in drain pipe in the
room wall and tighten it with a clip.