This Quick Start guide is intended as an overview to help experienced installers unpack, install, and configure an
Embedded Switch Module quickly. For more detailed installation and configuration instructions, see the Brocade
5450 Embedded Switch Module Hardware Reference Manual.
NOTE
Throughout this document, the Brocade 5450 Embedded Switch Module is referred to as the Embedded Switch
Module.

Installation and safety considerations

The Embedded Switch Module is designed to work in I/O bays 3 through 6 of the BX900 Blade Server chassis. Refer
to the PRIMERGY BX900 S1 Basic Unit Operating Manual and make sure to comply with installation requirements.

Installing multiple switches

Each Embedded Switch Module must be assigned a unique Ethernet IP address during configuration. Once the
default Ethernet IP address on the Embedded Switch Module has been changed, you may install additional
Embedded Switch Modules in the chassis.
If you do not have a DHCP server, install and configure one Embedded Switch Module at a time. This is required so
that Ethernet IP address conflicts do not occur with duplicate default Ethernet IP addresses.
Refer to the PRIMERGY BX900 S1 Basic Unit Operating Manual for help identifying your specific enclosure setup,
available connections, and power requirements.

Electrical considerations

The Embedded Switch Module requires 35 watts nominal (maximum of 50 watts), provided by the chassis. No other
power requirement or provision exists.

Environmental considerations

Ensure proper cooling and ventilation by verifying the following:
The air vents on the chassis are not blocked or restricted.
The ambient air temperature at the front of the enclosure does not exceed 35º C (95º F) while the Embedded
Switch Module is operating.
Brocade 5450 Embedded Switch Module QuickStart Guide
Publication Number: 53-1001265-02
3 of 20