Replacement routines
V
CAUTION!
Advise the customer that he must provide you with TPM backup copies.
For security reasons, the TPM must be restored/re-saved by the
customer. If the customer DOES NOT have a backup copy available,
inform him that replacing the TPM will cause him to lose all his data.
Ê Open the server and remove the air duct as described in
ration" on page
Ê Lay the server on its left side (as seen from the front).
Ê Remove all external cables.
Ê Remove the system fan 2 as described in
fan 2" on page 29
Ê Remove all controllers from their slots (for a description see the Operating
Manual and the Options Guide). Take note of the slots of the controllers and
the cabling.
Ê Remove the heat sink and the processor as described in
processor" on page
Ê Remove the memory modules (for a description see the Options Guide).
Ê Remove all cables which may be connected to the system board.
TX100 S1
17.
35.
Service Supplement
Replacing the system board
section "Prepa-
section "Replacing the system
"Replacing the
41