- ページ 20

サーバー Fujitsu PRIMERGY TX150 S6のPDF サービス補足マニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu PRIMERGY TX150 S6 45 ページ。
Fujitsu PRIMERGY TX150 S6 にも: 使用上の注意 (8 ページ)

Fujitsu PRIMERGY TX150 S6 サービス補足マニュアル

Replacing the standard PS

Ê Push the new operating panel module into its bay as far as it is possible to
have access to the cable tie.
Ê Thread the cables through the cable tie.
Ê Push the operating panel module into its bay as far as it is possible to plug
the cables.
Ê Connect the cables (ribbon cable, USB cable and perhaps ServerView Local
Service Panel cable) to the operating panel board (see the board layout on
page
39).
Ê Push the operating panel module into the housing until it engages.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.3
Replacing the standard PS
Ê Open the server as described in the
I
You can replace the power supply without removing the adapter plate.
Ê Disconnect all power cables from the system board and the drives (see the
cabling plans in the Options Guide).
Figure 3: Removing the screws
Ê Remove the four screws of the standard power supply (see the circles).
20
section "Preparation" on page
Service Supplement
Replacement routines
17.
TX150 S6