- ページ 5

アンプ A-M Systems 3000のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。A-M Systems 3000 18 ページ。 Ac/dc differential amplifier

A-M Systems 3000 取扱説明書
connected for proper operation. Usually the
indifferent lead. If you desire to have the current constrained to a known path you may
want to place the
Mode Controls
ELECTRODE TEST:
squarewave current source used to test electrode resistance and to adjust the
capacitance compensation. The
switch must be set to
STIM-GATEREC
Recording and reference electrodes should be in a saline solution for resistance
testing.) To accurately measure the impedance, verify at the
the signal is a square wave of 100 Hz, adjust the
square the corners of the waveform. The amplitude of the square wave is a direct
measure of impedance in each of the six ranges (0.1Vp-p/MΩ, 0.2Vp-p/MΩ, 1Vp-
p/MΩ, 2Vp-p/MΩ, 10Vp-p/MΩ, 20Vp-p/MΩ).
This isolated BNC connector enables a stimulus source to be utilized to
STIMULUS:
pass current through the electrode while the unit is in stimulate mode (
center pin of the BNC is the + input and the outer conductor is the - stimulus input.
When the unit is in the (STIM) mode the output will be a measure of the current
passing through the electrode in six ranges (5V/mA, 10V/mA, 50mV/µA, 0.1V/µA,
0.2V/ µA, or 1V/µA).
This toggle switch controls the operating mode for the Model 3000.
STIM-GATE-REC:
The switches allows the user to select Record Mode (
Gate Mode (
GATE
Output
Output: This BNC connector provides the output signal from the amplifier.
This connector on the front panel provides access to the circuit ground. Either
GND:
the
connector or the front panel
PROBE GND
operation. Usually the
desire to have the current constrained to a known path you may want to place the
elsewhere. Actual
GND
recordings a ground connection should be made in the recording medium (i.e. bath
ground, animal ground, etc.).
This rotary switch controls the level of signal gain for its channel while the
GAIN:
channel is in Record, Stimulate, and Impedance Mode. In Record mode (
switch allows the user to select from
Stimulate mode (
µA, 0.1V/µA, 0.2V/µA, or 1V/µA). In Impedance test mode (
A-M Systems
elsewhere. Actual
GND
This toggle switch activates (Ω
ELECT TEST
).
connector is tied to the indifferent lead. If you
PROBE GND
placement depends on the application. For low-noise
GND
) the gain switch selects one six ranges (5V/mA, 10V/mA, 50mV/
STIM
131 Business Park Loop, P.O. Box 850 Carlsborg, WA 98324
Telephone: 800-426-1306 * 360-683-8300 * FAX: 360-683-3525
E-mail: [email protected] * Website:
PROBE GND
placement depends on the application.
GND
) a 2 nA p-p, 100 Hz
TEST
switch must be set to Ω
for the test signal to be monitored. (Note:
REC
CAPACITY COMPENSATION
REC
must be connected for proper
GND
X50, X100, X500, X1000, X5000,
http://www.a-msystems.com
connector is tied to the
and the
TEST
connector that
OUTPUT
). The
STIM
) Stimulate Mode (
REC
or
X10,000
, Ω
) the gain
REC
TEST
knob to
), or
STIM
) the
gain. In
2